Teledyne LeCroy
Categories
Probemart.com | Probes, current sensors & calibration sources for pulsed-power testing
Bookmark
Teledyne LeCroy
Categories
The PP007-WR-1 is a 500 MHz / 10:1 passive voltage probe; its 2.5 mm slim probe diameter suits measurements on densely spaced pins, input impedance is 10 MΩ, input capacitance is 9.5 pF, and maximum input voltage is 400 V. It is intended primarily for WaveRunner 6000(A) and WaveRunner Xi(A) models above 1 GHz.
——— Related Applications ———
——— Related Products ———
PMK FireFly®FF-1500A optically isolated probe 1.3 GHz/1.5 GHz high CMRR (180 dB) high-voltage 2500 V double-pulse VGS gate /VDS drain voltage
IWATSU multi-channel high-voltage high-frequency optically isolated measurement probe Isolation SE-6000 remote UHV safety test system
CIC high-voltage differential probe DP20-20K-LVC high-precision 0.1% high-frequency isolated high CMRR 20 kV
| Parameter | Value |
| Bandwidth | 500 MHz |
| Attenuation ratio | 10:1 |
| Input impedance | 10 MΩ |
| Input capacitance | 9.5 pF |
| Maximum input voltage | 400 V |
| Cable length | 1.2 m |
| Connector type | BNC |
| Probe diameter | 2.5 mm |
| Attenuation setting identification pin | Yes |