News Center

Probemart.com | Probes, current sensors & calibration sources for pulsed-power testing

Bookmark Bookmark
Home > About Us > News Center
Cybertek OP6035A Optically Isolated Probe: Performance Upgra

Cybertek OP6035A Optically Isolated Probe: Performance Upgrade

Optically isolated probe product upgrade.

Views: 1223

06-11

2024
Rogowski Coils for High-Current Measurement Rogowski coils m

Rogowski Coils for High-Current Measurement

Rogowski coils measure AC currents and high-speed current pulses.

Views: 1755

06-02

2024
Fluxgate Zero-Flux Current Transformers in UHV GIS Testing V

Fluxgate Zero-Flux Current Transformers in UHV GIS Testing

Views: 1587

06-02

2024
Magnetic Measurement Basics: Converting Gauss to Tesla High-

Magnetic Measurement Basics: Converting Gauss to Tesla

High-: 1μG = 0.1nT, 1mG = 100nT, 1G = 100μT, 10G = 1mT, 10,000G = 1T deg (B) and (H): () medium-B=μoH. μ o = 4pi x 10-7 H/m SI, B, H A /m A/m. therefore, medium-, = 796kA/m. c μ o = 1, B high-, H 1 high- = 1

Views: 2095

01-14

2024
Danisense DCCT Ultra-Precision DC Current Sensors: How They

Danisense DCCT Ultra-Precision DC Current Sensors: How They Work

A fluxgate works by using an excited coil of soft magnetic material as the probe; saturation/desaturation cycling and signal processing let the coil measure the magnetic field proportionally. This opens up several current-sensor designs: it can simply replace an air-gap Hall probe, and the coil can take a split form.

Views: 4094

01-03

2024
Danisense Fluxgate Current Sensors: Technology and Principle

Danisense Fluxgate Current Sensors: Technology and Principles

The Danisense fluxgate is a proprietary closed-loop compensation technique with a fixed excitation frequency and second-harmonic zero-flux detection. The field produced by the primary current in the ring core is cancelled by a compensating secondary current from the integrator: the fluxgate senses the sub-ppm field from DC to below 100 Hz and instructs the integrator to compensate, while at higher frequencies the feedback winding detects the field and again corrects it.

Views: 2473

01-03

2024
T&M SSDN, SDN, 1M and A-Type Non-Inductive Coaxial Shunts (C

T&M SSDN, SDN, 1M and A-Type Non-Inductive Coaxial Shunts (CVR)

Views: 1002

12-12

2023
Micsig Optically Isolated Probes for SiC and GaN: MOIP1000P,

Micsig Optically Isolated Probes for SiC and GaN: MOIP1000P, MOIP500P, MOIP200P

SiC and GaN devices combine high breakdown voltage, low on-resistance and small parasitics. In switch-mode power supplies they cut losses, allow higher switching frequency and improve efficiency, power density and reliability. Optically isolated probes reproduce the VGS drive waveform with high fidelity.

Views: 959

12-12

2023
Tektronix IsoVu TIVP vs. High-Voltage Differential Probes: V

Tektronix IsoVu TIVP vs. High-Voltage Differential Probes: VGS Waveform Fidelity

Views: 1076

12-12

2023
MMCX Adapters for Optically Isolated Probes: Coaxial Connect

MMCX Adapters for Optically Isolated Probes: Coaxial Connector Performance Compared

Views: 1071

11-16

2023
  • «
  • 1
  • 2
  • 3
  • 4
  • 5
  • »