Cybertek
Categories
Probemart.com | Probes, current sensors & calibration sources for pulsed-power testing
Bookmark
Cybertek
Categories

The CPL8100C/D series products are current probes capable of measuring both DC and AC currents. They are industry-unique instruments that combine oscilloscope probes and clamp meters into one device. They can display the effective value of current directly without connecting to any equipment, and they can also be connected to an oscilloscope to measure waveforms. The display accuracy of the clamp meter function is up to 4.5 digits. They feature a dual power supply system with both battery and USB, which is a unique innovation in the industry.
The CPL8100C/D can measure currents up to 100A peak (70.7A RMS). The CPL8100C has a bandwidth of 600kHz (-3dB), while the CPL8100D has a bandwidth of 2MHz (-3dB). Two range options are provided (10A and 100A ranges), allowing selection of the appropriate range according to the current magnitude. They have an auto zero function for ease of use, power and low battery indicators, and an overload alarm sound. Power can be supplied either by batteries or an external power source, making measurement more convenient. A standard BNC output interface allows easy connection to oscilloscopes and other equipment. A BNC to dual banana plug adapter can be used to measure AC and DC currents with a multimeter. The LCD display shows DC to 400Hz effective values. These devices are commonly used in situations such as power frequency measurements, motor drives, and power supplies.
——— Related Applications ———
——— Related Products ———
PMK FireFly®FF-1500A optically isolated probe 1.3 GHz/1.5 GHz high CMRR (180 dB) high-voltage 2500 V double-pulse VGS gate /VDS drain voltage
IWATSU multi-channel high-voltage high-frequency optically isolated measurement probe Isolation SE-6000 remote UHV safety test system
CIC high-voltage differential probe DP20-20K-LVC high-precision 0.1% high-frequency isolated high CMRR 20 kV
Electrical characteristics
Measurement conditions:23℃, 60% RH, no current-carrying wires nearby, the measured conductor passes through the center test, load impedance1MΩ.
Gear |
L |
H |
||
Current range |
50mA~10Apeak |
1A~100Apeak |
||
BNCOutputRangesensitivity |
0.1V/A |
0.01V/A |
||
LCD display value |
DC~400HzRMS |
|||
TypicalDCaccuracy |
3%±50mA |
500 metersA~40Apeak value:4%±50mA; 40A~100Apeak value:±15% of the maximum value |
||
|
Bandwidth (-3dB) |
DC-600kHz Refer to the typical amplitude-frequency response(Figure 1) |
|||
| Maximum Current vs. Frequency Characteristic Curve | Reference image3 |
|||
Phase Shift |
DC~65Hz:1.5° |
DC~65Hz:1° |
||
typicalDClinearity |
InTypical DC linearity reference diagram in H gear (0.01V/A)4 |
|||
rise time |
≤583ns |
|||
Maximum operating current |
See the voltage and current rating table |
|||
Maximum operating voltage |
See the voltage and current rating table |
|||
Maximum Floating Voltage |
See the voltage and current rating table |
|||
Operating voltageRMS |
CAT I 600V CAT II 600V CAT III 300V |
|||
common-mode voltageRMS |
CAT I 600V CAT II 600V CAT III 300V |
|||
Typical Battery Types and Lifespan |
4festival5Numberalkaline battery/ 72hour |
|||
Low Battery Indicator Function |
When the battery voltage 4.3Vtime, Battery indicator light red alarm |
|||
Overload indicator function |
The measured current exceeds the range, and the buzzer sounds |
|||