Cybertek
Categories
Probemart.com | Probes, current sensors & calibration sources for pulsed-power testing
Bookmark
Cybertek
Categories

The DP6000 series high-voltage differential probes are high-voltage differential probes with floating ground measurement capability. Their bandwidth reaches up to 70MHz, meeting the needs of most testing systems; a wide range of measurement options is available, and their differential voltage measurement range satisfies the requirements of most test circuits; users can enter test mode to adjust the bias voltage. If offset occurs after long-term use of the probe, users can enter this mode to adjust the bias and achieve zeroing; electronic touch buttons extend the service life; a 5MHz bandwidth limit function is selectable, allowing measurement of the switching frequencies of FETs in most switching power supplies while filtering out higher-frequency noise and interference; the probe features a sound and light alarm function, which can be manually muted for more user-friendly operation; a USB power interface makes usage more convenient and flexible; the probe is equipped with a standard BNC output interface, compatible with oscilloscopes from any manufacturer (the oscilloscope input impedance should be set to 1MΩ; if 50Ω is selected, the attenuation factor will double) to measure the waveform of the circuit under test; an automatic save function prevents repeated operations after power loss. The probe has good common-mode noise suppression capability, with high input impedance and low capacitance at the input, enabling accurate and high-speed measurement of differential voltage signals. It can be widely used for the development, debugging, or repair of switching power supplies, inverters, electronic ballasts, variable-frequency appliances, and other electrical power devices.
——— Related Applications ———
——— Related Products ———
PMK FireFly®FF-1500A optically isolated probe 1.3 GHz/1.5 GHz high CMRR (180 dB) high-voltage 2500 V double-pulse VGS gate /VDS drain voltage
IWATSU multi-channel high-voltage high-frequency optically isolated measurement probe Isolation SE-6000 remote UHV safety test system
CIC high-voltage differential probe DP20-20K-LVC high-precision 0.1% high-frequency isolated high CMRR 20 kV
Electrical specifications
Model Number |
DP6350 |
||
Bandwidth(-3dB) |
70MHz |
||
rise time |
≤5ns |
||
Accuracy |
±2% |
||
Range selection(attenuation ratio) |
100X/1000X |
||
|
Maximum differential measurement voltage (DC Peak AC) |
100X |
±350V |
|
1000X |
±3500V |
||
common-mode voltage(DC Peak AC) |
±3500V |
||
Maximum differential-mode voltageVS frequency curve |
Reference image2 |
||
Maximum input-to-ground voltage (Vrms) |
600V CATIII 1000V CAT II |
||
Input impedance |
Single-ended to ground |
5 MΩ |
|
Between two input terminals |
10 MΩ |
||
Input capacitance |
Single-ended to ground |
<4pF |
|
Between two input terminals |
<2pF |
||
CMRR |
DC |
>80dB |
|
100 kHz |
>60dB |
||
1 MHz |
>50dB |
||
noise(Vrms) |
100X |
<100mV |
|
1000X |
<600mV |
||
Overload indication voltage threshold |
100X |
≥350V |
|
1000X |
≥3500V |
||
Delay time |
Probe main unit |
9ns |
|
BNC cable (1m) |
5ns |
||
Bandwidth limit(5MHz) |
≥-3dB@5MHz |
||
Overload Indicator Light(red light) |
there are |
||
Overload audible alarm |
there are(Optional to turn off) |
||
Auto-save function |
there are |
||
Adjustable offset (bias) function |
Yes (adjustable in test mode) |
||
Terminal load requirement |
≥100 kΩ |
||
Power supplies |
USB 5V/2A Adapter |
||
Safety compliance standards |
EN61010-1: 2010 |
||
EMCCompliance standards |
EN61326-1:2013 EN61000-3-2:2006 A1:2009 A2:2009 EN61000-3-3:2013 |
||