The DP6000D series high-voltage differential probes are high-voltage differential probes with floating ground measurement capability. They feature a high bandwidth of up to 500MHz, meeting the needs of most testing systems; a wide range of selectable measurement spans, with differential measurement voltage ranges suitable for most test circuits; users can enter the test mode to adjust the offset voltage, and if imbalance occurs after long-term use, users can enter this mode to adjust the offset to achieve zeroing; electronic touch buttons extend the lifespan; there is a 5MHz bandwidth limiting function available, and the 5MHz frequency bandwidth meets the measurement requirements of most switching frequency FETs in power supplies and can filter out higher-frequency noise and interference; it has audio-visual alarm functions and the sound alarm can be manually turned off, making it more user-friendly; USB power supply interface for more convenient and flexible use; the probe comes with a standard BNC output interface, which can be used with oscilloscopes from any manufacturer (requires the oscilloscope input impedance to be set to 50Ω (preferably using the internal 50Ω of the oscilloscope), or connect the standard through-type 50Ω load, and set the oscilloscope input impedance to 1MΩ) to measure the waveform of the circuit under test; automatic save function to prevent repeated operation after power loss. The probe has good common-mode noise suppression capability, with high input impedance and low capacitance at the input end, allowing accurate and high-speed measurement of differential voltage signals. It can be widely used in the research, debugging, or maintenance of switching power supplies, inverters, electronic ballasts, variable frequency home appliances, and other electrical power devices.
——— Related Applications ———
——— Related Products ———
PMK FireFly®FF-1500A optically isolated probe 1.3 GHz/1.5 GHz high CMRR (180 dB) high-voltage 2500 V double-pulse VGS gate /VDS drain voltage
IWATSU multi-channel high-voltage high-frequency optically isolated measurement probe Isolation SE-6000 remote UHV safety test system
CIC high-voltage differential probe DP20-20K-LVC high-precision 0.1% high-frequency isolated high CMRR 20 kV
Electrical specifications
Model Number |
DP6350D |
||
Bandwidth(-3dB) |
500 MHz |
||
rise time |
≤700ps |
||
Accuracy |
±2% |
||
Range selection(attenuation ratio) |
200X/2000X |
||
|
Maximum differential measurement voltage (DC Peak AC) |
200X |
±350V |
|
2000X |
±3500V |
||
common-mode voltage(DC Peak AC) |
±3500V |
||
Maximum differential-mode voltageVS frequency curve |
Reference image3 |
||
Maximum input-to-ground voltage (Vrms) |
600V CAT III 1000V CAT II |
||
Input impedance |
Single-ended to ground |
5 MΩ |
|
Between two input terminals |
10 MΩ |
||
Input capacitance |
Single-ended to ground |
<4pF |
|
Between two input terminals |
<2pF |
||
CMRR |
DC |
>80dB |
|
100 kHz |
>60dB |
||
1 MHz |
>50dB |
||
noise(Vrms) |
200X |
<350mV |
|
2000X |
<730mV |
||
Overload indication voltage threshold |
200X |
≥350V |
|
2000X |
≥3500V |
||
Delay time |
Probe main unit |
6 ns |
|
BNC cable (1m) |
5ns |
||
Bandwidth limit(5MHz) |
≥-3dB@5MHz |
||
Overload Indicator Light(red light) |
there are |
||
Overload audible alarm |
there are(Optional to turn off) |
||
Auto-save function |
there are |
||
Adjustable offset (bias) function |
Yes (adjustable in test mode) |
||
Terminal load requirement |
50Ω |
||
Power supplies |
USB 5V/2A Adapter |
||
Safety compliance standards |
EN61010-1: 2010 |
||
EMCCompliance standards |
EN61326-1:2013 EN61000-3-2:2006 A1:2009 A2:2009 EN61000-3-3:2013 |
||