The DP6000B series high-voltage differential probes are high-voltage differential probes with floating ground measurement capabilities. They have a maximum bandwidth of 300MHz, meeting the needs of most testing systems; they offer a variety of selectable ranges, and their differential measurement voltage range satisfies the requirements of most test circuits. Users can enter a test mode to adjust the offset voltage; if the probe becomes unbalanced after prolonged use, users can enter this mode to adjust the offset and achieve zeroing. The electronic touch button extends the service life. There is a 5MHz bandwidth limit option; the 5MHz bandwidth meets the switching frequency measurement requirements of most FETs in switching power supplies and can filter out higher frequency noise and interference. The probe has both audible and visual alarm functions, and the audible alarm can be manually turned off, making the design more user-friendly. It has a USB power supply interface for more convenient and flexible use. The probe is equipped with a standard BNC output interface, compatible with oscilloscopes from any manufacturer (the oscilloscope input impedance must be set to 1MΩ; if 50Ω is selected, the attenuation factor will be doubled) to measure the waveforms of the circuit under test. It has an automatic save function to prevent repeated operations after power loss. The probe provides good common-mode noise suppression, with high input impedance and low capacitance at the input, allowing accurate and high-speed differential voltage measurements. It can be widely used in the research, debugging, or maintenance of switching power supplies, inverters, electronic ballasts, variable frequency home appliances, and other electrical power devices.
——— Related Applications ———
——— Related Products ———
PMK FireFly®FF-1500A optically isolated probe 1.3 GHz/1.5 GHz high CMRR (180 dB) high-voltage 2500 V double-pulse VGS gate /VDS drain voltage
IWATSU multi-channel high-voltage high-frequency optically isolated measurement probe Isolation SE-6000 remote UHV safety test system
CIC high-voltage differential probe DP20-20K-LVC high-precision 0.1% high-frequency isolated high CMRR 20 kV
Electrical specifications
Model Number |
DP6700B |
||
Bandwidth(-3dB) |
300 MHz |
||
rise time |
≤1.16ns |
||
Accuracy |
±2% |
||
Range selection(attenuation ratio) |
200X/2000X |
||
|
Maximum differential measurement voltage (DC Peak AC) |
200X |
±700V |
|
2000X |
±7000V |
||
common-mode voltage(DC Peak AC) |
±7000V |
||
Maximum differential-mode voltageVS frequency curve |
Reference image4 |
||
Maximum input-to-ground voltage (Vrms) |
1000V CAT III 2300V CAT I |
||
Input impedance |
Single-ended to ground |
20 MΩ |
|
Between two input terminals |
40 MΩ |
||
Input capacitance |
Single-ended to ground |
<5pF |
|
Between two input terminals |
<2.5 pF |
||
CMRR |
DC |
>80dB |
|
100 kHz |
>60dB |
||
1 MHz |
>50dB |
||
noise(Vrms) |
200X |
<550mV |
|
2000X |
<1V |
||
Overload indication voltage threshold |
200X |
≥700V |
|
2000X |
≥7000V |
||
Delay time |
Probe main unit |
6ns |
|
BNC cable (1m) |
5ns |
||
Bandwidth limit(5MHz) |
≥-3dB@5MHz |
||
Overload Indicator Light(red light) |
there are |
||
Overload audible alarm |
there are(Optional to turn off) |
||
Auto-save function |
there are |
||
Adjustable offset (bias) function |
Yes (adjustable in test mode) |
||
Terminal load requirement |
≥100 kΩ |
||
Power supplies |
USB 5V/2A Adapter |
||
Safety compliance standards |
EN61010-1: 2010 |
||
EMCCompliance standards |
EN61326-1:2013 EN61000-3-2:2006 A1:2009 A2:2009 EN61000-3-3:2013 |
||