Cybertek
Categories
Probemart.com | Probes, current sensors & calibration sources for pulsed-power testing
Bookmark
Cybertek
Categories

The HCPR8000 series current probe is a high-frequency current probe capable of measuring both DC and AC. Its features include high bandwidth, high accuracy, and 232 serial communication functionality. When used in conjunction with our intelligent probe controller OT7052, customers can read the probe's status on a PC through the intelligent probe controller, intelligently switch probe ranges, automatically demagnetize and zero, and more. The OT7052 effectively addresses the power supply and communication control issues for up to 52 intelligent probes in an automated test system.
——— Related Applications ———
——— Related Products ———
PMK FireFly®FF-1500A optically isolated probe 1.3 GHz/1.5 GHz high CMRR (180 dB) high-voltage 2500 V double-pulse VGS gate /VDS drain voltage
IWATSU multi-channel high-voltage high-frequency optically isolated measurement probe Isolation SE-6000 remote UHV safety test system
CIC high-voltage differential probe DP20-20K-LVC high-precision 0.1% high-frequency isolated high CMRR 20 kV
bigPliers jaw
Model Number |
HCPR8150(A) |
HCPR8300(A) |
HCPR8500 |
|||
Bandwidth(-3dB) |
HCPR8150 |
DC-12 MHz (Figure10.a) |
HCPR8300 |
DC- 6 MHz (Figure 13.a) |
DC-5MHz (Figure 16) |
|
HCPR8150A |
DC-22 MHz (Figure10.b) |
HCPR8300A |
DC-8 MHz (Figure 13.b) |
|||
rise time |
HCPR8150 |
≤29ns |
HCPR8300 |
≤58ns |
≤70 ns |
|
HCPR8150A |
≤16 ns |
HCPR8300A |
≤50 ns |
|||
Maximum continuous current |
HCPR8150 |
150Arms (Figure11.a) |
HCPR8300 |
300Arms (Figure 14.a) |
500Arms(Figure 17) |
|
HCPR8150A |
150Arms (Figure11.b) |
HCPR8300A |
300Arms (Figure 14.b) |
|||
Peak current |
300Apk |
500Apk |
750Apk |
|||
Range |
30A |
10Xattenuation |
50A |
10Xattenuation |
75A |
10Xattenuation |
150A |
100Xattenuation |
300A |
100Xattenuation |
500A |
100Xattenuation |
|
Overcurrent Alarm Value |
30A |
≥30APK |
50A |
≥50APK |
75A |
≥75APK |
150A |
≥300APK |
300A |
≥500APK |
500A |
≥750APK |
|
Current transmission ratio |
30A |
0.1V/A |
50A |
0.1V/A |
75A |
0.1V/A |
150A |
0.01V/A |
300A |
0.01V/A |
500A |
0.01V/A |
|
resolution |
30A |
10mA |
50A |
10mA |
75A |
10mA |
150A |
100mA |
300A |
100mA |
500A |
100mA |
|
|
Accuracy (DC, 45-66Hz)Maximum continuous currentwithin the scope) |
30A |
±1%±10mA |
50A |
±1%±10mA |
75A |
±1%±10mA |
150A |
±1%±100mA |
300A |
±1%±100mA |
500A |
±1%±100mA |
|
Input impedance |
HCPR8150 |
Reference (Figure12.a) |
HCPR8300 |
Reference (Figure15.a) |
Reference(Figure 18) |
|
HCPR8150A |
Reference (Figure12.b) |
HCPR8300A |
Reference (Figure15.b) |
|||
|
Delay(Probe main unit 1 meterBNC) |
Reference (Figure19) |
|||||
Terminal load requirement |
≥100 kΩ |
|||||
Power supply method |
OT7052 |
|||||
Insulated wire voltage |
600V CAT II 300V CAT III |
|||||
Safety compliance standards |
EN61010-1: 2010 A1:2019 EN 61010-2-032:2019 |
|||||
EMCCompliance standards |