Fischer Custom Communications
Categories
Probemart.com | Probes, current sensors & calibration sources for pulsed-power testing
Bookmark
Fischer Custom Communications
Categories

Whenever RF current needs to be measured, a current monitoring probe can be used.Current measurement is performed by placing the current-carrying conductor within the probe's "sensing" window and using an RF detector to measure the probe's output voltage.Calibration of the probe allows the measured voltage to be converted to current.Current measurement can be performed over the frequency range indicated by the transfer impedance curve supplied with each probe.There is almost no circuit loading, and this technique allows the device under test to operate normally during measurement.
——— Related Applications ———
——— Related Products ———
PMK FireFly®FF-1500A optically isolated probe 1.3 GHz/1.5 GHz high CMRR (180 dB) high-voltage 2500 V double-pulse VGS gate /VDS drain voltage
IWATSU multi-channel high-voltage high-frequency optically isolated measurement probe Isolation SE-6000 remote UHV safety test system
CIC high-voltage differential probe DP20-20K-LVC high-precision 0.1% high-frequency isolated high CMRR 20 kV
| PRODUCT | FREQUENCY Frequency bandwidth |
DB (NOMINAL) | ZT (NOMINAL) |
Connector interface |
INNER DIAMETER (MM.) Inner diameter |
OUTER DIAMETER (MM.) Outer diameter |
HEIGHT (MM.) Height |
MAX PRIMARY CURRENT DC-400HZ Maximum primary current |
CW CURRENT (A) Continuous wave current |
Peak Pulse Current pulsed currentpeak value |
CALIBRATION FIXTURE calibrationFixture |
| F-110305-1005-1 | 10 kHz - 1 GHz | - | 1 | Type-N | 32 | 71 | 19 | 100 | 5 | 100 | FCC-MPCF-3-32-40/71/19 |
| F-14 | 10 Hz - 500 kHz | -18 | 0.12 | Type-N | 32 | 94 | 64 | 400 | 5 | 500 | FCC-MPCF-1-32/94/64 |
| F-14A | 10 Hz - 500 kHz | -18.5 | 0.12 | Type-N | 67 | 142 | 53 | 400 | 25 | 500 | FCC-MPCF-2-67/142/53 |
| F-170302-1005-1 | 10 Hz - 50 MHz | -60 | 0.001 | Type-N | 40 | 80 | 19 | 20 | 2 | 2000A (8x20 slots) | FCC-MPCF-2-32-40/71/19 |
| F-170308-1005-1 | 10 Hz - 50 MHz | -3 | 0.7 | Type-N | 67 | 142 | 53 | 50 | 10 | 100 | FCC-MPCF-2-67/142/53 |
| F-170317-1005-1 | 100 kHz - 300 MHz | 11 | 3.5 | Type-N | 305 | 395 | 51 | 1000 | 5 | 100 | FCC-MPCF-2-305/394/51 |
| F-170329-1005-1 | 10 kHz - 30 MHz | 3 | 1.4 | Type-N | 67 | 142 | 53 | 1000 | 2 | 100 | FCC-MPCF-2-67/142/53 |
| F-170705-1005-1 | 100 kHz - 30 MHz | 6 | 2 | Type-N | 67 | 142 | 53 | 750 | 10 | 100 | FCC-MPCF-2-67/142/53 |
| F-170710-1005-1 | 10 kHz - 400 MHz | -9 | 0.35 | Type-N | 32 | 71 | 19 | 50 | 2 | 100 | FCC-MPCF-2-32-40/71/19 |
| F-170804-1005-1 | 10 kHz - 400 MHz | 14 | 5 | Type-N | 65 | 104 | 19 | 150 | 2 | 100 | F-080902-1005-2 |
| F-170804-1005-2 | 10 kHz - 250 MHz | 11 | 3.5 | Type-N | 65 | 104 | 19 | 750 | 2 | 100 | - |
| F-180907-1005-1 | 10 kHz - 108 MHz | 14 | 5 | Type-N | 127 | 197 | 41 | 500 | 10 | 100 | FCC-MPCF-1-127/197/41 |
| F-180907-1005-2 | 10 kHz - 108 MHz | Ø | 1 | Type-N | 127 | 197 | 41 | 500 | 10 | 100 | FCC-MPCF-1-127/197/41 |
| F-180907-1005-3 | 10 Hz - 1 MHz | -20 | 0.1 | Type-N | 127 | 197 | 41 | 1000 | 10 | 100 | FCC-MPCF-1-127/197/41 |
| F-190717-1005-1 | 100 Hz - 750 MHz | -47 | 0.0045 | Type-N | 40 | 98 | 38 | 200 | 2 | 3000/5000 | - |
| F-2000-12mm | 10 MHz - 3 GHz | 23 | 14 | SMA | 12 | 37 | 17 | 100 | 1 | 10 | FCC-MPCF-2K Rev B |
| F-2000-32mm-1 | 10 MHz - 2.1 GHz | 25 | 18 | Type-N | 32 | 71 | 19 | 350 | 3 | 100 | F-050315-1005-1 |
| F-2000-40mm-1 | 10 MHz - 2.1 GHz | 22 | 12.5 | Type-N | 40 | 80 | 19 | 350 | 3 | 100 | F-050315-1005-2 |
| F-200921-1005-1 | 1 kHz - 750 MHz | - | - | Type-N | 40 | 98 | 38 | 500 | 3 | 100 | FCC-MPCF-3-32-40/98/38 |
| F-200921-1005-2 | 10 kHz - 400 MHz | - | - | Type-N | 40 | 98 | 38 | 500 | 3 | 100 | FCC-MPCF-2-32-40/98/38 |
| F-200921-1005-4 | 10 kHz | - | - | Type-N | 40 | 98 | 38 | 600 | 3 | 100 | - |
| F-201015-1005-1 | 10 kHz - 400 MHz | - | - | Type-N | 40 | 125 | 19 | 240 | 3 | 100 | - |
| F-210602-1005-1 | 10 kHz - 400 MHz | - | - | Type-N | 70 | 125 | 38 | 400 | 40 | 100 | FCC-MPCF-2-70/125/38 |
| F-210602-1005-2 | 10 kHz - 400 MHz | - | - | Type-N | 70 | 125 | 38 | 400A | 40 | 100 | FCC-MPCF-2-70/125/38 |
| F-210930-1005-1 | 10 Hz - 250 MHz | - | - | Type-N | 65 | 142 | 54 | 1000 | 100/5000 | 100 | - |
| F-220114-1005-1 | 10 kHz - 1 GHz | - | - | - | 32 | 71 | 19 | 400 | 3 | 100 | FCC-MPCF-3-32-40/71/19 |
| F-220121-1005-1 | 10 kHz - 1 GHz | -20 | - | Type-N | 32 | 71 | 19 | 400 | 3 | 100 | FCC-MPCF-3-32-40/71/19 |
| F-220124-1005-1 | 10 kHz - 1 GHz | -9 | 0.35 | Type-N | 32 | 71 | 19 | 50 | 2 | 100 | FCC-MPCF-3-32-40/71/19 |
| F-220126-1005-1 | 10 kHz | - | - | Type-N | 40 | 125 | 21 | 600 | 2 | 100 | FCC-MPCF-2-40/125/21 |
| F-220126-1005-2 | 10 kHz - 400 MHz | - | - | Type-N | 70 | 125 | 38 | 600 | 2 | 100 | FCC-MPCF-2-70/125/38 |
| F-220815-1005-1 | 10 Hz - 400 MHz | - | - | Type-N | 67 | 142 | 53 | 1200 | 50/200 | 200/2000 | - |
| F-230824-1005-1 | 10 kHz - 30 MHz | - | - | Type-N | 32 | 71 | 19 | 250 | 3 | 100 | - |
| F-230912-1005-1 | 10 kHz - 400 MHz | - | - | Type-N | 70 | 125 | 38 | 500 | 3 | 100 | - |
| F-33-2 | 1 kHz - 250 MHz | Ø | 1 | Type-N | 32 | 71 | 19 | 100 | 2 | 50 | FCC-MPCF-2-32-40/71/19 |
| F-35A-L | 10 Hz - 108 MHz | Ø | 1 | Type-N | 32 | 98 | 38 | 200 | 3 | 100 | FCC-MPCF-2-32-40/98/38 |
| F-37-2 Clip-On | 10 kHz - 1 GHz | Ø | 1 | SMA | 12 | 44 | 18 | 100 | 10 | 100 | FCC-MPCF-37-2 |
| F-38-1 Clip-On | 10 kHz - 200 MHz | 9 | 2.8 | SMA | 5 | 54 | 10 | 20 | 1 | 10 | FCC-MPCF-F-38 |
| F-38-2 Clip-On | 1 kHz - 200 MHz | Ø | 1 | SMA | 5 | 54 | 10 | 20 | 1 | 10 | FCC-MPCF-F-38 |
| F-38-4 Clip-On | 1 MHz - 1 GHz | 14 | 5 | SMA | 5 | 54 | 10 | 20 | 1 | 10 | FCC-MPCF-F-38 |
| F-39-1 | 10 kHz - 200 MHz | 9 | 2.8 | SMA | 18 | 85 | 6 | 20 | 1 | 10 | FCC-MPCF-39 |
| F-39-2 | 1 kHz - 200 MHz | Ø | 1 | SMA | 18 | 85 | 6 | 20 | 1 | 10 | FCC-MPCF-39 |
| F-39-4 | 1 MHz - 1 GHz | 6 | 2 | SMA | 18 | 85 | 6 | 20 | 1 | 10 | FCC-MPCF-39 |
| F-40-5 | 10 Hz - 50 MHz | -20 | 0.1 | Type-N | 67 | 142 | 53 | 1000 | 60 | 5000 | FCC-MPCF-2-67/142/53 |
| F-42A | 1 kHz - 100 MHz | 12 | 4 | Type-N | 32 | 71 | 19 | 50 | 2 | 100 | FCC-MPCF-2-32-40/71/19 |
| F-52B | 10 kHz - 400 MHz | 13 | 4.5 | Type-N | 40 | 80 | 19 | 200 | 2 | 100 | FCC-MPCF-2-32-40/71/19 |
| F-57 | 1 kHz - 500 MHz | Ø | 1 | Type-N | 40 | 98 | 38 | 200 | 2 | 100 | FCC-MPCF-2-32-40/98/38 |
| F-75B | 1 kHz - 500 MHz | Ø | 1 | Type-N | 70 | 125 | 38 | 200 | 3 | 100 | FCC-MPCF-2-70/125/38 |