IWATSU
Categories
Probemart.com | Probes, current sensors & calibration sources for pulsed-power testing
Bookmark
IWATSU
Categories


OpECS optically isolated current probe
■ Ultra-small probe tip (tip circumference approx. 0.45 mm)
■ Current detection can be performed without clamping for short-range non-contact measurement
■Bandwidth up to 150 MHz, maximum measured current up to 140 A
Recommended application scenarios:
◆ Current measurement on power semiconductor wiring packages
◆ Current measurement on high-density PCB boards
◆ Measurement of switching waveforms of SiC/GaN devices
◆ Measurement of current flowing through wires such as air-core coils
OpEOSIt is an optical current sensor that performs current measurement by capturing the magnetic field generated around the current. This series uses the Faraday effect (or magneto-optic effect). When the sensor is in a magnetic field, the oscillation direction of linearly polarized light changes under the influence of the magnetic field. Depending on the direction of the magnetic field, the oscillation direction follows an elliptical path, and the change in direction is proportional to the magnetic field strength. The signal is sent to the control unit at a later stage, where it is converted from an optical signal to an electrical signal. The converted electrical signal can then be input to an oscilloscope or other equipment to measure current.
Positional relationship between the wire and the sensor
As shown in1the figure at position ①, when the probe portion contacts the center of the wire, maximum sensitivity is obtained. When placed as in ①, a positive output is obtained relative to the current direction through the wire; when placed as in ②, an inverted output is obtained. When the probe tip is moved away from the wire center, as shown in ③, the magnetic field weakens and the sensitivity changes, as shown in2the figure. Therefore, by maintaining an appropriate distance, the desired sensitivity can be obtained.


Figure 1.Connection between the electric wire and probeFigure 2. Distance from the wire center and sensitivity (x-axis unit:mm, y-axis unit:mV/A)
In addition, if the distance between the wire center and the probe remains constant, even if the wire diameter changes, the probe measurement resultwill not change either, as shown in3shown.

Figure 3. Relationship between sensing distance and wire diameter
Probe linearity
OpECSThe linearity of the current probe is shown in4the figure. At ±140Amaintains ± within the range1%linearity.

Figure 4. Linearity of the current sensor output
——— Related Applications ———
——— Related Products ———
PMK FireFly®FF-1500A optically isolated probe 1.3 GHz/1.5 GHz high CMRR (180 dB) high-voltage 2500 V double-pulse VGS gate /VDS drain voltage
IWATSU multi-channel high-voltage high-frequency optically isolated measurement probe Isolation SE-6000 remote UHV safety test system
CIC high-voltage differential probe DP20-20K-LVC high-precision 0.1% high-frequency isolated high CMRR 20 kV
Data sheet
Parameters |
Specifications |
Bandwidth |
DC-150MHz(-3dB) |
Peak current |
±140A |
Sensitivity |
25.78 mV/A |
Output voltage range |
±4.7V |
noise |
6.3 mVrms |
Linearity |
±1% |
Output interface |
BNC |
Voltage output range |
AC85~264V(50/60Hz) |
Power consumption |
19W |
Probe head | |
Tip shape |
0.45 X 1mm |
Weight |
Approx.5g |
Control unit | |
Dimensions |
244.0 X 290.0 X 144.0mm |
Weight |
Approx.3.4 kg |
Sensor heads in various shapes are still under development.