Keysight Technologies
Categories
Probemart.com | Probes, current sensors & calibration sources for pulsed-power testing
Bookmark
Keysight Technologies
Categories

Lower current range limit: 50 uA
Upper current range limit: 5 A
Normal dynamic range: >1,000:1 or 60 dB
Bandwidth
- 3 MHz - reduced channel
- 500 kHz - amplified channel
Well suited for capturing and analyzing low-level currents in devices under test to characterize subcircuits, or for measuring the current consumption of wireless battery-powered devices or integrated circuits
Perform normal dynamic range measurements using selectable high-gain or low-gain views of the current waveform
Probe accessories can be included with the probe or ordered separately: replaceable sensor head, MBB socket, connectors, and connection cables
As modern battery-powered devices and integrated circuits become more environmentally friendly and energy-efficient, high-sensitivity, low-level current measurements are increasingly required to ensure that the current consumption of these devices is within permissible limits. The N2821A high-sensitivity probe is designed for high-dynamic-range, high-sensitivity measurements to meet today's challenging current measurement requirements.
The ultra-sensitive N2821A AC/DC current probe supports measurements from 50 uA to 5 A on Keysight oscilloscopes. The N2821A interface uses make-before-break (MBB) connectors, allowing you to quickly probe multiple locations on the device under test without soldering or desoldering leads.
The N2820A dual-channel current probe connects to two oscilloscope channels to simultaneously provide low-gain and high-gain views for wider dynamic range measurements, while the N2821A single-channel current probe provides only one user-selectable view at a time.
Combined with Infiniium S-series high-definition oscilloscopes, it provides a complete high-sensitivity measurement solution. Using the area-under-the-curve (charge) measurement on Infiniium oscilloscopes, you can easily calculate integrated current consumption over a period of time (in coulombs).
For detailed information on high-sensitivity AC/DC current probes, visit Keysight N2820A high-sensitivity current probe。
——— Related Applications ———
——— Related Products ———
PMK FireFly®FF-1500A optically isolated probe 1.3 GHz/1.5 GHz high CMRR (180 dB) high-voltage 2500 V double-pulse VGS gate /VDS drain voltage
IWATSU multi-channel high-voltage high-frequency optically isolated measurement probe Isolation SE-6000 remote UHV safety test system
CIC high-voltage differential probe DP20-20K-LVC high-precision 0.1% high-frequency isolated high CMRR 20 kV