Probemart.com | Probes, current sensors & calibration sources for pulsed-power testing

Bookmark Bookmark
Home > Products > Instruments
Teledyne LeCroy high-frequency low-volta Teledyne LeCroy Catalog
Teledyne LeCroy high-frequency low-voltage differential probe DH25-PX type 25 GHz high-bandwidth isolated oscilloscope voltage
  • Teledyne LeCroy high-frequency low-voltage differential probe DH25-PX type 25 GHz high-bandwidth isolated oscilloscope voltage

Teledyne LeCroy high-frequency low-voltage differential probe DH25-PX type 25 GHz high-bandwidth isolated oscilloscope voltage

Brand: Teledyne LeCroy

Origin: USA

Isolated Voltage Probe. Detailed specifications are available in the product datasheet.
Overview

LeCroy DH Series high-frequency low-voltage differential probes:


DH08-PB2 - 8 GHz differential probe with ProBus2 interface 

DH08-PL - 8 GHz differential probe with ProLink interface 

DH13-PL - 13 GHz differential probe with ProLink interface 

DH16-PL - 16 GHz differential probe with ProLink interface 

DH20-PL - 20 GHz differential probe with ProLink interface 

DH25-PX - 25 GHz differential probe with ProAxial interface 

DH30-PX - 30 GHz differential probe with ProAxial interface 

DH-CSPHY-PCIE5-CEMX16 - DH Series tip - CrossSync PHY PCIe5 CEM x16 

DH-SI-HS - DH Series high-sensitivity solder-in tip, 30 GHz BW, 2.0 Vpp range 

DH-SI - DH Series solder-in tip, 30 GHz bandwidth, 3.5 Vpp range 

DH-HTEMP - DH Series high-temperature solder-in tip, 16 GHz BW, 3.5 Vpp range 

DH-QL - DH Series QuickLink adapter, 8 GHz bandwidth 

DH-QL-3SI - DH Series QuickLink adapter kit with 3 x QL-SI tips 

Dehydrogenase - DH Series PT browser tip, 16 GHz bandwidth, 3.5 Vpp range 




Key features


  • Bandwidth models from 8 GHz to 30 GHz

  • Low loading and high impedance, with minimal signal interference


  • Various tip types:

  • Standard and high-sensitivity 30 GHz solder-in tips

  • High-temperature solder-in tip with 1 m lead

  • QuickLink adapter for mixed-signal probing

  • Handheld adjustable browser tip

  • Front end for connecting an oscilloscope directly to CrossSync PHY protocol analyzer interposers

  • Built-in tip identification for easy setup and accurate signal reproduction


  • Well suited for debugging and validation:

  • DDR3/LPDDR3

  • DDR4/LPDDR4/LPDDR4X

  • DDR5

  • Other high-speed serial interfaces



 

General-purpose probing up to 30 GHz

Teledyne LeCroy DH series 8 to 30 GHz differential probes provide a combination of bandwidth, input range, and offset capability to meet any high-speed probing requirement from debugging serial data interfaces to validating DDR memory systems. DH series probes provide excellent loading characteristics and are calibrated with a custom “tuned” frequency response. Ultra-low loading and flat frequency response ensure accurate measurements.

Smart probes for all applications

Two 30 GHz solder-in tips let you choose a 3.5 Vpp input range for general-purpose applications or high sensitivity with exceptionally low noise. Also available are a 1 m long 16 GHz high-temperature solder-in tip, a 16 GHz browser tip, and a QuickLink adapter for connecting mixed-signal probe tips. The same solder-in, high-temperature, and QuickLink tips are compatible with all DH series probes and can be interchanged among any probe in the series, maximizing flexibility in the laboratory. Each tip contains its own identification and calibration data for accurate signal reproduction and excellent ease of use.

Solder-in tips (DH-SI and DH-SI-HS)

The 30 GHz DH series solder-in tips are very compact for accessing signals on densely laid-out circuit boards, and the 9-inch lead length helps reach hard-to-probe locations. The standard DH-SI solder-in tip has a 3.5 Vpp input range and is well suited for DDR memory and other general-purpose high-speed serial signal applications. For smaller signals where noise performance is critical, the DH-SI-HS high-sensitivity solder-in tip has a 2.0 Vpp input range and excellent noise performance.

High-temperature probe (DH-HITEMP)

For tests that require placing equipment in an environmental chamber, the DH-HITEMP head can separate the solder-in probe tip from the probe amplifier by up to 1 m. The head has 16 GHz bandwidth, a 3.5 Vpp input range, and an operating temperature range of -40°C to +125°C, making it well suited for environmental testing of various high-speed devices.

Handheld browser tip (DH-PT)

Where fast access to multiple test points is critical, the DH-PT browser tip provides 16 GHz bandwidth in a convenient “pencil” form factor. The included free-hand probe holder enables simple hands-free browsing.

CrossSync PHY cross-layer probe (DH-CSPHY)

CrossSync PHY technology enables waveforms from Teledyne LeCroy oscilloscopes to be displayed simultaneously with protocol analyzer traces, achieving complete time correlation of electrical and protocol information. Through a series of interposers that support CrossSync PHY, using special DH-CSPHY probe tips, DH series probes can be connected directly to high-speed signal lines.

QuickLink adapter (DH-QL)

The DH-QL adapter allows QuickLink solder-in probe tips to be used with any DH series probe. For embedded system validation and debugging, these probes can be used for analog probing with DH series probes and for digital acquisition with the HDA125 high-speed digital analyzer.

Mixed-signal flexibility

When connected to a Teledyne LeCroy analog differential probe, QuickLink probes provide 8 GHz bandwidth and a flat, well-controlled frequency response. When used with the HDA125 for digital acquisition, they support 3 GHz bandwidth and have industry-leading sensitivity. The HDA125 can directly acquire and analyze DDR command bus signals and other high-speed digital bus signals together with time-correlated analog signals on standard oscilloscope channels.

 


Specifications

DH Series.png

Expand Teledyne LeCroy high-frequency low-volta

* Specifications are subject to change without notice.