PEM
Categories
Probemart.com | Probes, current sensors & calibration sources for pulsed-power testing
Bookmark
PEM
Categories

PEM Rogowski Coil CWT-CWTHF Datasheet datasheet.pdf
PEM CWT Rogowski Coil Technical Note - Low-Frequency Performance CWT-Technical-notes-Low-Frequency-performance-Probemart.pdf
PEM CWT Rogowski Coil Technical Note - Delay and Rise Time CWT Technical Note – Delay and Rise TimeProbemart.pdf
PEM CWT Rogowski Coil Application Note application_notes-Probemart.pdf
PEM CWT Integrator Module Fuse Replacement Instructions for CWT Integrator Module Fuse ReplacementProbemart.pdf
PEM CWT Application Article High Performance Rogowski Current Transducers-W.F.Ray C.R.Hewson Probemart.pdf
PEM CWT Minimum Measurable Current Application Article -Probemart.pdf
PEM CWT Accurate Measurement in High-Power Motor Power Conversion Application -Probemart.pdf
PEM CWT Rogowski Coil Immunity to Coupled Voltage Interference Technical Note CWT-Technical-notes-Voltage-immunity-Probemart.pdf
PEM Rogowski Coil - A Next-Generation Current Probe for High-Speed, High-Power Measurements -Chrise Hewson.pdf
PEM- Rogowski Coil Practical Fast-Switching Current Measurement in Power Electronics Chris Hewson, APEC-March-2015.pdf
The CWT wideband high-current Rogowski coils mainly include: CWT standard series, CWT LF low-frequency series, CWT mini series, CWT miniHF series, CWT Mini 50HF, CWT Ultra Mini, CWT LF, and other products.
_________________________________________________
CWT Standard Main Performance Parameters:
Peak current: 30A - 600kA peak
Output: ±6.0V (full scale); high-frequency bandwidth (-3dB): 16MHz
Accuracy (typical): up to ±0.2% at the center position of the coil
Operating temperature range: 0℃ to +40℃ (integrator); –20℃ to +100℃ (coil + cable)
Coil length: 300, 500, 700 or 1000mm (custom lengths available)
Coil insulation: 10kV peak
Coil diameter: 8.5mm
Cable length: 2.5m or 4m (custom lengths available)
Power supply: AA battery or 12V DC power adapter
_______________________________________________________
CWT Standard Main Features:
Traceable calibration data (including certificate)
Non-contact measurement has no effect on the circuit under test
No magnetic material means excellent linearity
Complete isolation from DC current allows measurement of small ripple currents superimposed on large DC currents
Exceeding the current range causes no damage
——— Related Applications ———
——— Related Products ———
PMK FireFly®FF-1500A optically isolated probe 1.3 GHz/1.5 GHz high CMRR (180 dB) high-voltage 2500 V double-pulse VGS gate /VDS drain voltage
IWATSU multi-channel high-voltage high-frequency optically isolated measurement probe Isolation SE-6000 remote UHV safety test system
CIC high-voltage differential probe DP20-20K-LVC high-precision 0.1% high-frequency isolated high CMRR 20 kV
| Parameter | Value |
|---|---|
| Peak Current | 30000 A |
| High Frequency Bandwidth | 16 MHz |
| Low Frequency Cut-off | 0.2 Hz |
| Frequency Bandwidth | 16 / 12.5 / 10 / 8 MHz (300 / 500 / 700 / 1000 mm) (by coil length) |
| Peak di/dt | 40 kA/µs |
| Droop Rate | 0.2 %/ms |
| Sensitivity | 0.2 mV/A |
| Noise | 3 mV (p-p, peak-to-peak) |
| Coil Withstand Voltage | 10 kV |
| Operating Temperature | -20~+100 °C |
| Zero Adjustment | No |
| Coil Diameter | 8.5 mm |
| Coil Length | 300~1000 mm |
| Cable Length | 1 / 2.5 / 4 m |