Probemart.com | Probes, current sensors & calibration sources for pulsed-power testing

Bookmark Bookmark
Home > Products > Instruments
PMK high-frequency high- BNC probe PKT s PMK Catalog
PMK high-frequency high- BNC probe PKT series 500 MHz high-bandwidth 400 V / 1650 V peak voltage 10:1, 100:1 BNC
  • PMK high-frequency high- BNC probe PKT series 500 MHz high-bandwidth 400 V / 1650 V peak voltage 10:1, 100:1 BNC

PMK high-frequency high- BNC probe PKT series 500 MHz high-bandwidth 400 V / 1650 V peak voltage 10:1, 100:1 BNC

Brand: PMK

Origin: Germany

PKT cable typical application (and), BNC BNC. system bandwidth up to 500 MHz, rise time 700ps. with high-frequency. standard temperature range 0 °C to +50
Overview

Passive Cable Distribution Series PKT

■ Up to 500MHz, 400V / 1650V peak value

■ 10:1, 100:1 BNC-BNC model

■ Suitable for harsh environments

■ Dual-End High-Frequency Compensation

■ Different cable lengths

■ Output terminal 50Ω AC/DC

■ Optional Read

■ Optional Siliconisolation



A typical application of the PKT cable distributor is its installation on vibrating equipment (such as machines and engines), with a BNC-to-BNC connection.

The system bandwidth can reach up to 500 MHz, with a typical rise time of 700 ps. The PKT cable distributor has high-frequency adjustability.

The operating temperature range for standard manufacturing is 0 °C to 50 °C.

An optional silicone tube insulation body connects the cable distributor with high voltage insulation, and an optional reinforced steel tension relief device enhances its resistance to mechanical impact.

The passive BNC-BNC cable distributor PKT of PMK can come with or without silicon (S), and can come with or without smart readout (RO) functionality.

Has intelligent communication with automatic calibration on the oscilloscope display.

All passive cable distributors undergo calibration at the end of production. The factory calibration certificate is optional.

The readout (RO) in our probe is a physical pin located in the BNC converter.

This output pin allows the settings of oscilloscope (such as ratio) to be automatically adjusted according to the attenuation factor of probe to ensure that the readings on probe are correct.


Specifications

000.png

Parameter Value
Pollution Degree 2
Attenuation Ratio 10:1 (PKT512 A-RO); 100:1 models also available in the series
Series / Model PKT series high-frequency high-impedance passive divider probe (BNC output)
Attenuation Accuracy ± 2 % @ DC
Voltage Coefficient 0.00025 % / V
System Bandwidth (-3 dB) 500 MHz (PKT512A-RO)
System Rise Time (10 %-90 %) 700 ps
Max Rated Input, CAT I 400 V rms, 1250 V transient overvoltage
Max Rated Input, CAT II 300 V
Derating max input voltage decreases with increasing frequency (see derating curve)
Order Number (example) 858-512-A01 (PKT512A-RO)
Expand PMK high-frequency high- BNC probe PKT s

* Specifications are subject to change without notice.