400V 差分输入、500MHz 带宽、100:1 衰减的高压差分探头,4档可切换量程,2m 线缆。适用于 SiC/GaN 双脉冲 VDS、开关电源与逆变器测量。
优势应用:SiC/GaN双脉冲VDS测量;开关电源;电机驱动/逆变器;IGBT电路;变频器;4档量程兼顾低噪与分辨率
资料来源:(P1) pmkamerica.com/collections/bumblebee
——— Related Applications ———
——— Related Products ———
PMK FireFly®FF-1500A optically isolated probe 1.3 GHz/1.5 GHz high CMRR (180 dB) high-voltage 2500 V double-pulse VGS gate /VDS drain voltage
IWATSU multi-channel high-voltage high-frequency optically isolated measurement probe Isolation SE-6000 remote UHV safety test system
CIC high-voltage differential probe DP20-20K-LVC high-precision 0.1% high-frequency isolated high CMRR 20 kV
| Parameter | Value |
| Order Number | 880-122-501 |
| Attenuation Ratio (optional) | 100:1 / 50:1 / 20:1 / 10:1 (± 1 % guaranteed) |
| Bandwidth (-3 dB), small signal | 100:1, 50:1: 500 MHz; 20:1, 10:1: 400 MHz |
| Rise Time (10 %-90 %), small signal | 100:1, 50:1: 0.8 ns; 20:1, 10:1: 0.95 ns |
| Max Rated Input Voltage | 400 V rms / 1000 V transient overvoltage (no measurement category) |
| CAT Rating | 150 V CAT II |
| Pollution Degree | 2 |
| Max Differential Input Voltage | 100:1 ± 400 V; 50:1 ± 200 V; 20:1 ± 80 V; 10:1 ± 40 V (DC + AC peak) |
| Common Mode Voltage | ± 400 V peak (280 V rms) |
| DC Gain Accuracy | 100:1, 50:1: ± 0.35 %; 20:1, 10:1: ± 0.7 % |
| Propagation Delay | 12 ns (2 m) / 28 ns (6 m) / 32.5 ns (7 m), ± 0.5 ns |
| Noise (AC rms) | 100:1, 50:1: 14 mV rms; 20:1, 10:1: 11 mV rms |
| Input Impedance (each side to GND) | 1.125 MΩ ∥ 5 pF |
| Differential Input Capacitance | 2.5 pF |
| Input Capacitance (each side to GND) | 5 pF |
| Differential Input Impedance | 2.25 MΩ ∥ 2.5 pF |
| CMRR (Common Mode Rejection Ratio) | DC: 80 dB; 100 kHz: 70 dB; 3.2 MHz: 62 dB; 10 MHz: 50 dB; 50 MHz: 45 dB; 100 MHz: 40 dB; 400 MHz: 35 dB |
| Input Coupling (measuring instrument) | 50 Ω |
| Offset Correction Range | ± 4 V (output) |
| Offset Resolution | min. 13 bit / V (min. 1 mV) |
| Offset Drift | 40 µV / °C |
| Cable Length | 2 m |
| Input Lead Length | 25 cm |
| Input Lead Connector | 2 mm x 4 mm (male) |
| Output Connector | BNC (male) |
| Weight (probe only) | 370 g (probe only) |
| Power Supply | PS-02 / PS-03 power supply (USB, optional LAN) or AP-01 battery pack (1 channel, > 8 h) |
| Operating Temperature | 0 °C ~ +50 °C |
| Storage Temperature | -40 °C ~ +71 °C |
| Maximum Relative Humidity | Operating: 80 % RH up to +31 °C, decreasing linearly to 40 % at +50 °C (non-condensing); non-operating: 95 % up to +40 °C |
| Altitude | Operating: up to 2000 m; non-operating: up to 15000 m |
| Calibration | factory-optional ISO 17025 calibration (initial or re-calibration) |
| DC Accuracy | ± 0.35 % |