PMK
Categories
Probemart.com | Probes, current sensors & calibration sources for pulsed-power testing
Bookmark
PMK
Categories

Automobile industry: Support durability and functional testing of ECUs, inverters, sensors, and battery management systems under extreme temperature cycles.
Power electronics and industrial field: Can achieve safe and accurate signal acquisition in the thermal stress testing of devices such as power modules, gate driver devices, and converters.
Research and development laboratories, universities, and scientific research institutions: Suitable for material research or sensor development, it can capture precise analog signals or high-speed digital signals during controlled environmental changes.
Aerospace, rail transit, energy systems, and other fieldsIn scenarios with extremely high reliability requirements under harsh working conditions, the ENVI® P (U) HT probe can provide stable and reliable Solutions without the need for active circuits or temperature compensation.

ENVI®probe tested in a -41°C illusion.
Key features:
1. Extremely wide operating temperature range
The core advantage of the ENVI high-temperature probe lies in its high-temperature performance. Both the probe and accessories can operate normally over the temperature range of -55°C to 155°C. The application range is as follows:
High-temperature process equipment such as metal furnaces and glass furnaces;
Extreme-temperature measurement;
Measurements in high-temperature environments such as automotive engines and brake systems.
2. Good high-frequency response characteristics
probe bandwidth is for350MHz, capable of quickly responding to signal changes. This means it can operate stably at high frequencies, suitable for applications that require fast sampling and data transmission.
3. High input voltage capability
Input voltage is400V, up to a maximum of 1250V, which allows probe to adapt to a wider voltage range and meet application requirements in different environments. Its input impedance is 4.5MΩ, with an input capacitance of 20pF, and these parameters make probe more sensitive and stable in response to input signals.
4. Good stability and reliability
The ENVI high-temperature probe undergoes strict quality control and testing to ensure stable performance under harsh environments such as high temperature and high voltage. Its design uses advanced temperature isolation technology, which can effectively prevent temperature changes from affecting measurement accuracy.
5. Technical specifications
High temperature resistance range:-55°C to 155°C
Bandwidth:500 MHz
Input voltage: overshoot1250V
input impedance:4.5 MΩ
Input capacitor:20pF
Attachment temperature resistance: can withstand the same as probe-55℃ to 155℃ high temperature
GermanyPMK's ENVI High-Temperature Resistant probe, with its excellent high-temperature resistance, stable input characteristics, and wide range of applications, has become an ideal choice for modern industrial and electronic fields. Whether it is high-temperature industrial measurement, automotive electronic systems, or communication systems, this probe can provide users with reliable measurement results thanks to its high performance and reliability. If you need precise measurements in extreme environments, the ENVI High-Temperature Resistant probe will be your best choice.
——— Related Applications ———
——— Related Products ———
PMK FireFly®FF-1500A optically isolated probe 1.3 GHz/1.5 GHz high CMRR (180 dB) high-voltage 2500 V double-pulse VGS gate /VDS drain voltage
IWATSU multi-channel high-voltage high-frequency optically isolated measurement probe Isolation SE-6000 remote UHV safety test system
CIC high-voltage differential probe DP20-20K-LVC high-precision 0.1% high-frequency isolated high CMRR 20 kV

| Parameter | Value |
| Type | passive probe with integrated high/low temperature construction, for use inside climatic chambers |
| Input Impedance (system) | 4.5 MΩ, ± 1 % |
| Compensation Range | 10 pF ~ 25 pF |
| Order Number | 835-312-U01 |
| Series | ENVI® @PUHT ultra-high temperature passive probe |
| Attenuation Ratio | 10:1, ± 2 % @ DC |
| Operating Temperature | -55 °C ~ +200 °C |
| Input Capacitance (system) | 20 pF |
| Pollution Degree | 3 |
| System Bandwidth (-3 dB) | 500 MHz |
| Max Rated Input | |
| Input Coupling of Measuring Instrument | 1 MΩ AC / DC |