Siglent Technologies
Categories
Probemart.com | Probes, current sensors & calibration sources for pulsed-power testing
Bookmark
Siglent Technologies
Categories

The ODP6000B series products are fiber-optic isolated voltage probes with ultra-high common-mode rejection ratio. Traditional differential probes' common-mode rejection rapidly decreases at high frequencies,
making it extremely difficult to accurately measure small voltage signal waveforms under high common-mode interference voltages (such as measuring the drive voltage of transistors in a half-bridge circuit).
The ODP6000B series adopts a high-performance laser fiber optic signal transmission system, thus providing ultra-high common-mode rejection across the entire operating bandwidth,
helping customers complete such challenging measurements at a very low cost.
Product Features:
⚫ Dual batteries provide longer operating time
⚫ Online calibration and zeroing without disconnecting from the device under test
⚫ Various attenuators available to meet different voltage measurement needs
⚫ Extremely high common-mode rejection ratio
⚫ Bandwidth up to 1 GHz
⚫ Isolation voltage 60 kV
⚫ High stability, low temperature drift
⚫ Smaller size
Applications
Can be widely used in the development, debugging, or maintenance of switching power supplies, motor drives, new energy inverters, frequency converters, lighting power supplies, variable frequency home appliances, and other electrical power devices.
⚫ Floating signal testing
⚫ Measuring gate drive voltages of Si/SiC/GaN power devices
⚫ Differential small signal measurement under high common-mode voltage conditions
The ODP6000B series optical isolation probes employ a unique dual battery replaceable technology, ensuring customers can measure without interruption. Using standard digital camera lithium batteries, if the battery fails after several years of use, customers can purchase this universal rechargeable battery themselves without returning it to the factory for replacement,
avoiding potential damage during shipping and reducing measurement downtime, thereby improving measurement efficiency.
——— Related Applications ———
——— Related Products ———
PMK FireFly®FF-1500A optically isolated probe 1.3 GHz/1.5 GHz high CMRR (180 dB) high-voltage 2500 V double-pulse VGS gate /VDS drain voltage
IWATSU multi-channel high-voltage high-frequency optically isolated measurement probe Isolation SE-6000 remote UHV safety test system
CIC high-voltage differential probe DP20-20K-LVC high-precision 0.1% high-frequency isolated high CMRR 20 kV
| Parameters | Model | ODP6050B | ODP6100B |
|---|---|---|---|
| bandwidth (-3dB) | 500 MHz | 1 GHz | |
| rise time | ≤0.7 ns | ≤0.4 ns | |
| Terminal load | 50 Ω | 50 Ω | |
| Output voltage range | ±0.5 V | ±0.5 V | |
| Host noise (Vrms) Typical Value | 1.5 mV | 1.5 mV | |
| Direct current accuracy | ≤±1% | ≤±1% | |
| isolated voltage measurement (DC Peak AC) | ±60 kV | ±60 kV | |
| Host latency | approximately 14 ns | approximately 14 ns | |
| CMRR typical value (using standard attenuator) |
DC-10 MHz: 160 dB 10 MHz-100 MHz: 110 dB 100 MHz-300 MHz: 100 dB 300 MHz-500 MHz: 90 dB |
500 MHz-800 MHz: 80 dB 800 MHz-1000 MHz: 70 dB |
|
| ODP6035B standard configuration 20X attenuator | (ODP6050B/ODP6100B standard 50X attenuator) | - | |
| Power supply method | Frontend: Battery powered, working time approximately 8 hours, standby duration about 30 days. Backend: USB 5 V/2 A | Same as the left | |
| automatically calibrate | there are | there are | |
| probe Size | Front-end Electro-Optical Emitter | About 1024533 mm | About 1024533 mm |
| Backend optoelectronic receiver | About 1064923 mm | About 1064923 mm | |
| attenuator Length | About 200 mm | About 200 mm | |
| Fiber optic cable length | about 2 m | about 2 m | |
| probe Weight | About 400 g | About 400 g |
| probe Model | attenuator Model | Connector type | Attenuation ratio | Test Scope | Input impedance | ||
|---|---|---|---|---|---|---|---|
|
ODP6050B
ODP6100B |
CK-AT5X-2 | SSMB | 5:1 | ±2.5 V peak | 1 MΩ | 28 pF | |
| CK-AT10X-2 | SSMB | 10:1 | ±5 V peak | 1 MΩ | 6 pF | ||
| CK-AT20X-2 | SSMB | 20:1 | ±10 V peak | 5 MΩ | 6 pF | ||
| CK-AT50X-2 | SSMB | 50:1 | ±25 V peak | 10 MΩ | 4 pF | ||
| CK-AT100X-2 | SSMB | 100:1 | ±50 V peak | 10 MΩ | 2 pF | ||
| CK-AT200X-2 | SSMB | 200:1 | ±100 V peak | 10 MΩ | 2 pF | ||
| CK-AT500X-2 | 2.54 mm socket | 500:1 | ±250 V peak | 10 MΩ | 2 pF | ||
| CK-AT1000X-2 | 2.54 mm socket | 1000:1 | ±500 V peak | 20 MΩ | 2 pF | ||
| CK-AT2000X-2 | 5.08 mm socket | 2000:1 | ±1000 V peak | 20 MΩ | 2 pF | ||
| CK-AT5000X-2 | 5.08 mm socket | 5000:1 | ±2500 V peak | 40 MΩ | 2 pF | ||
| CK-AT10000X-2 | 5.08 mm socket | 10000:1 | ±5000 Vpk | 40 MΩ | 2 pF |