The DP1007A high-voltage differential probe is suitable for all mainstream oscilloscopes on the market,
converting floating signals into low-voltage signals referenced to ground, allowing any oscilloscope with a ground reference to safely and easily display them.
The probe can be used at frequencies up to 70MHz and can handle voltage signals up to 700V,
with high common-mode rejection capability, making it an excellent choice for non-ground-referenced, floating, or isolated measurements.
This oscilloscope differential probe is ideal for power testing, switching power supplies, inverters, motor drive control, switching power supply R&D, and maintenance evaluation.
Product Features
• Safe floating-ground measurements
• Will not damage the oscilloscope or the device under test
• Strong anti-interference capability
• Audible and visual alarm function
• 5MHz bandwidth limit function selection
• Good common-mode noise suppression capability
——— Related Applications ———
——— Related Products ———
PMK FireFly®FF-1500A optically isolated probe 1.3 GHz/1.5 GHz high CMRR (180 dB) high-voltage 2500 V double-pulse VGS gate /VDS drain voltage
IWATSU multi-channel high-voltage high-frequency optically isolated measurement probe Isolation SE-6000 remote UHV safety test system
CIC high-voltage differential probe DP20-20K-LVC high-precision 0.1% high-frequency isolated high CMRR 20 kV
| Model | DP1007A |
| Bandwidth (-3dB) | 70 MHz |
| rise time | ≤5ns |
| Accuracy | ±2% |
| Range selection (attenuation ratio) | 10X/100X |
| Maximum differential measurement voltage |
10X: ±70V DC Peak AC 100X: ±700V DC Peak AC |
| common-mode voltage | ±700V DC Peak AC |
| Maximum input to ground voltage |
450VCAT II 600V CAT I Vrms |
| Input impedance |
Single-ended to ground: 2.5 MΩ ±1% Between the two input terminals: 5MΩ ±1% |
| Input capacitance |
Single-ended to ground: Between the two input terminals: |
| CMRR |
DC: >80dB 100KHz: >60dB 1MHz: >50dB 3.2MHz: >30dB 50MHz: >26dB |
| noise level |
10X: 100X: |
| Overload indication voltage threshold |
10X: ≥70V 100X: ≥700V |
| bandwidth Limit (5MHz) long | ≥-3dB@5MHz |
| Overload Indicator Light | There is a (red light) |
| Overload audible alarm | Available (can be turned off) |
| Auto-save function | there are |
| Adjustable offset (bias) function | Yes (adjustable in test mode) |
| Terminal load requirement | ≥100 kΩ |
| Power supplies | USB 5V/1A adapter |
| Safety compliance standards | EN61010-1:2010 |
| EMC compliance standards | EN61326-1:2013 EN61000-3-3:2013 |