UNI-T
Categories
Probemart.com | Probes, current sensors & calibration sources for pulsed-power testing
Bookmark
UNI-T
Categories

UT-PD2500 and UT-PD1500 It is designed for high-frequency measurement active differential probe, integrating many of the requirements needed for today's general high-speed probe. Features. active differential probe It is widely used in many high-speed fields such as high-speed digital circuits, bus analysis, and signal integrity analysis, and can be more Accurately and quickly obtaining signal information in a circuit helps improve engineers' work efficiency and accuracy.
Excellentelectrical performance
Height bandwidth-Accurately measure high-speed serial signals
UT-PD2500 Bandwidth:2.5GHz
UT-PD1500 Bandwidth:1.5GHz
Extremely high signal fidelity
UT-PD2500 rise time:150ps
UT-PD1500 rise time:245ps
Input dynamic range: ±4V
Input common-mode range: ±15V
Easy to useFunction probe
Automatic sensing attenuation factor
Automatically recognize probe model
Automatically read probe serial number
probe Bias Adjustment
probecalibration
probe tip Button oscilloscope Control
RichApplication environment
Commonly used in the design, verification, and debugging of high-speed serial buses
- I2C\SPI
- CAN\CAN-FD\LIN
- Serial ATA
- Ethernet (GbE)
- USB 2.0 -
FireWire(1394b)
Signal integrity, jitter analysis, and eye diagram
High-Speed Serial Bus Consistency Analysis
CompatibleOscilloscope
UNI-T Mid-to-high-end series oscilloscope
-MSO8000HD Series
-MSO7000X Series
-UPO7000L series
-MSO5000HD Series
-MSO3000HD series
-MSO3000X Series
——— Related Applications ———
——— Related Products ———
PMK FireFly®FF-1500A optically isolated probe 1.3 GHz/1.5 GHz high CMRR (180 dB) high-voltage 2500 V double-pulse VGS gate /VDS drain voltage
IWATSU multi-channel high-voltage high-frequency optically isolated measurement probe Isolation SE-6000 remote UHV safety test system
CIC high-voltage differential probe DP20-20K-LVC high-precision 0.1% high-frequency isolated high CMRR 20 kV
| Performance Indicators | UT-PD2500 | UT-PD1500 |
|---|---|---|
| probe bandwidth (-3dB) | 2.5GHz | 1.5GHz |
| rise time | ≤150ps | ≤245ps |
| Input capacitance | ≤1 pF | ≤1 pF |
| Input resistance | 200kΩ ±2% (differential) 100kΩ ±2% (single-ended) | 200kΩ ±2% (differential) 100kΩ ±2% (single-ended) |
| Output impedance | 50Ω | 50Ω |
| DC attenuation ratio | 10:1±5% | 10:1±5% |
| Input dynamic range | 8Vpp (±4V DC or peak AC) | 8Vpp (±4V DC or peak AC) |
| Input common-mode range | ±15V (from DC to 100Hz) ±2.5V (for >100Hz) | ±15V (from DC to 100Hz) ±2.5V (for >100Hz) |
| Bias range | ±4V | ±4V |
| Offset accuracy | ||
| Maximum input voltage | ±30V (DC peak AC), mains isolated | ±30V (DC peak AC), mains isolated |
| Flatness (typical value) | 0.5dB (100 kHz–500 MHz) 1dB (500MHz-2GHz) | 0.5dB (100 kHz–500 MHz) 1dB (500MHz-1.5GHz) |
| common-mode rejection ratio CMRR | 40dB at 1MHz 40dB at 30MHz 30dB at 1GHz | 40dB at 1MHz 40dB at 30MHz 30dB at 1GHz |
| noise (Equivalent to the input terminal) | 7mVrms(@10:1) | 7mVrms(@10:1) |
| Maximum Slew Rate | 30V/ns (differential, 10X), 15V/ns (single-ended, 10X) | 15V/ns (single-ended, 10X) |
| Zero offset error (equivalent at the input terminal) | ||
| Propagation delay | ≤7.5ns | ≤7.5ns |
| Electrostatic Protection | >8kV from 100pF, 300Ω, HBM | >8kV from 100pF, 300Ω, HBM |
| probeSpecification | ||
| Weight | ||
| Cable length | 1.2 meters | 1.2 meters |
| probe Size | - | - |
| Input interface | - | - |
| Compatible oscilloscope | MSO7000X Series MSO8000HD Series | MSO7000X Series MSO8000HD Series |