Cybertek
Categories
Probemart.com | Probes, current sensors & calibration sources for pulsed-power testing
Bookmark
Cybertek
Categories

The CP9000 (S/L) A series flexible current probe is a probe designed only for testing AC current signals, featuring high bandwidth and high accuracy (typical value 2%).
It can achieve a wide current measurement range, with frequencies from a few Hz to tens of MHz, and current ranges from the mA level to several kA, greatly addressing the challenges of current testing.
Its main features include:
The coil is lightweight, flexible, and can be freely plugged and unplugged, allowing it to reach places that many rigid probes cannot, easily connecting to the measured object;
The insertion loss is almost zero, only a few picohenries, causing nearly zero interference to the measured object;
Standard BNC output interface, convenient for connection to oscilloscopes, data acquisition devices, digital voltmeters, etc., for observing current waveforms;
Powered by four AA batteries or an external USB DC5V power supply, offering more flexible and convenient use;
Audio-visual overcurrent alarm function, with a more user-friendly design;
The probe loop and connection cable length can be customized according to customer requirements, meeting testing needs in special scenarios.
The CP9000LA series probe loop has a typical outer diameter of 8mm and a withstand voltage of up to 10kVpk, making it very suitable for high-current, high-power scenarios.
——— Related Applications ———
——— Related Products ———
PMK FireFly®FF-1500A optically isolated probe 1.3 GHz/1.5 GHz high CMRR (180 dB) high-voltage 2500 V double-pulse VGS gate /VDS drain voltage
IWATSU multi-channel high-voltage high-frequency optically isolated measurement probe Isolation SE-6000 remote UHV safety test system
CIC high-voltage differential probe DP20-20K-LVC high-precision 0.1% high-frequency isolated high CMRR 20 kV
(Measurement conditions: 23°C; 60% RH; the wire under test passes through the center of the probe induction loop.)
CP9000LA Series
Model |
Sensitivity(mV/A) |
peak Value |
Maximum noise(mV Vpp) |
Attenuation characteristics (%/ms) |
Low frequencybandwidth-3dB(Hz) |
High frequency bandwidth-3dB(MHz) |
Typicalaccuracy |
insulation Voltage value |
|
Current(kA) |
dI/dt (kA/µs) |
||||||||
CP9012LA |
50 |
0.12 |
0.8 |
3 |
70 |
80 |
10 |
1% |
10 kV |
CP9030LA |
20 |
0.3 |
2.0 |
2.5 |
40 |
50 |
10 |
||
CP9060LA |
10 |
0.6 |
4.0 |
8 |
2.0 |
2.1 |
10 |
||
CP9120LA |
5 |
1.2 |
8.0 |
8 |
2.0 |
2.1 |
10 |
||
CP9300LA |
2 |
3.0 |
20 |
7 |
1.1 |
1.2 |
10 |
||
CP9600LA |
1 |
6.0 |
40 |
5 |
1.1 |
1.2 |
10 |
||
CP9121LA |
0.5 |
12 |
40 |
3.5 |
1.1 |
1.2 |
10 |
||
CP9301LA |
0.2 |
30 |
40 |
3 |
0.35 |
0.5 |
10 |
||
CP9601LA |
0.1 |
60 |
40 |
3 |
0.35 |
0.5 |
10 |
||
CP9122LA |
0.05 |
120 |
40 |
3 |
0.35 |
0.5 |
10 |
||
CP9302LA |
0.02 |
300 |
40 |
3 |
0.35 |
0.5 |
10 |
||
CP9602LA |
0.01 |
600 |
40 |
3 |
0.35 |
0.5 |
10 |
||
CP9123LA |
0.005 |
1200 |
40 |
3 |
0.35 |
0.5 |
10 |
||