Probemart.com | Probes, current sensors & calibration sources for pulsed-power testing

Bookmark Bookmark
Home > Products > Instruments
Cybertek Rogowski current probe CP9000LA Cybertek Catalog
Cybertek Rogowski current probe CP9000LA series (8 mm)
  • Cybertek Rogowski current probe CP9000LA series (8 mm)

Cybertek Rogowski current probe CP9000LA series (8 mm)

Brand: Cybertek

Origin: China

CP9000LA series probe typical 8 mm, withstand voltage up to 10 kVpk, non- high-current, high-power applications
Overview


The CP9000 (S/L) A series flexible current probe is a probe designed only for testing AC current signals, featuring high bandwidth and high accuracy (typical value 2%).


It can achieve a wide current measurement range, with frequencies from a few Hz to tens of MHz, and current ranges from the mA level to several kA, greatly addressing the challenges of current testing.




    Its main features include:


  • The coil is lightweight, flexible, and can be freely plugged and unplugged, allowing it to reach places that many rigid probes cannot, easily connecting to the measured object;

  • The insertion loss is almost zero, only a few picohenries, causing nearly zero interference to the measured object;

  • Standard BNC output interface, convenient for connection to oscilloscopes, data acquisition devices, digital voltmeters, etc., for observing current waveforms;

  • Powered by four AA batteries or an external USB DC5V power supply, offering more flexible and convenient use;

  • Audio-visual overcurrent alarm function, with a more user-friendly design;

  • The probe loop and connection cable length can be customized according to customer requirements, meeting testing needs in special scenarios.




The CP9000LA series probe loop has a typical outer diameter of 8mm and a withstand voltage of up to 10kVpk, making it very suitable for high-current, high-power scenarios.


Specifications

 (Measurement conditions: 23°C; 60% RH; the wire under test passes through the center of the probe induction loop.)  

  CP9000LA Series

Model

Sensitivity(mV/A)

peak Value

Maximum noise(mV Vpp)

Attenuation characteristics

(%/ms)

Low frequencybandwidth-3dB(Hz)

High frequency bandwidth-3dB(MHz)

Typicalaccuracy

insulation

Voltage value

Current(kA)

dI/dt (kA/µs)

CP9012LA

50

0.12

0.8

3

70

80

10

1%

10 kV

CP9030LA

20

0.3

2.0

2.5

40

50

10

CP9060LA

10

0.6

4.0

8

2.0

2.1

10

CP9120LA

5

1.2

8.0

8

2.0

2.1

10

CP9300LA

2

3.0

20

7

1.1

1.2

10

CP9600LA

1

6.0

40

5

1.1

1.2

10

CP9121LA

0.5

12

40

3.5

1.1

1.2

10

CP9301LA

0.2

30

40

3

0.35

0.5

10

CP9601LA

0.1

60

40

3

0.35

0.5

10

CP9122LA

0.05

120

40

3

0.35

0.5

10

CP9302LA

0.02

300

40

3

0.35

0.5

10

CP9602LA

0.01

600

40

3

0.35

0.5

10

CP9123LA

0.005

1200

40

3

0.35

0.5

10



Expand Cybertek Rogowski current probe CP9000LA

* Specifications are subject to change without notice.