Probemart.com | Probes, current sensors & calibration sources for pulsed-power testing

Bookmark Bookmark
Home > Products > Instruments
Cybertek high-frequency low-voltage diff Cybertek Catalog
Cybertek high-frequency low-voltage differential probe DP6060A (60 V/800 MHz) isolated voltage
  • Cybertek high-frequency low-voltage differential probe DP6060A (60 V/800 MHz) isolated voltage

Cybertek high-frequency low-voltage differential probe DP6060A (60 V/800 MHz) isolated voltage

Brand: Cybertek

Origin: China

DP6060A (60 V/800 MHz) bandwidth (-3dB) 800 rise time ≤437ps
Overview

The DP6020A, DP6040A, and DP6060A probes are low-voltage differential probes with floating measurement capability. They can measure voltages of ±20V (DC Pk), 40V (DC Pk), and 60V (DC Pk) respectively, with a bandwidth of up to 800MHz. They offer attenuation settings of 10:1, 20:1, and 50:1, feature input impedances of 200KΩ and 400KΩ, and have low input capacitances of 1 pF and 0.5 pF, which helps minimize circuit loading. Equipped with overvoltage alarm functionality, they are compatible with any oscilloscope with a 50 Ω BNC input and can be powered via the USB port on an oscilloscope or computer. Widely used in various applications, they provide excellent general differential signal measurement for today’s high-speed power measurements, in-vehicle bus measurements, and digital system design.

Specifications

Electrical specifications

Model

DP6060A

Bandwidth(-3dB)

800 MHz

(Reference image2frequency response Curve)

rise time

≤437ps

Accuracy(Reading %)

±2%

Attenuation ratio

50:1

Maximum differential measurement voltage(DC Peak AC)

±60V

Maximum common-mode input voltage

±100V

Maximum rated input voltage (each terminal to ground)

±100V

Input impedance

Single-ended to ground

200kΩ

Between two input terminals

400kΩ

Input capacitance

Single-ended to ground

<1pF

Between two input terminals

<0.5pF

Output voltage swing

±1.2V (Drive 50ΩoscilloscopeInput)

Bias (typical value)

±5mV

Bias Adjustment Range (Typical Value)

±20mV

CMRR

50Hz/60Hz

>80dB

500MHz

>15dB

noise(Vrms)

<22mV

Overload indication voltage threshold

≥60V

Delay time

Probe main unit

6ns

BNC cable (1m)

5ns

Overload Indicator Light

When overloaded, the indicator light turns red.

Terminal load requirement

50Ω

Power supplies

USB 5V/2A Adapter

 image.png


Expand Cybertek high-frequency low-voltage diff