The DP6000 series high-voltage differential probes are high-voltage differential probes with floating ground measurement functionality.
Main Features of the DP6000 Series Products:
Its bandwidth reaches up to 200MHz, meeting the needs of most testing systems;
Offers a variety of ranges, with differential measurement voltage ranges that satisfy the requirements of most test circuits;
Users can enter the test mode to adjust the offset voltage. If the probe shows offset after long-term use, users can enter this mode to adjust the offset and achieve zeroing;
Electronic touch buttons ensure a longer service life;
Equipped with a 5MHz bandwidth limit option. The 5MHz frequency bandwidth meets the measurement needs of FET switching frequencies in most switching power supplies and can filter out higher-frequency noise and interference;
Features audible and visual alarms, with the option to manually turn off the sound alarm, providing more user-friendly design;
USB power supply interface for more convenient and flexible use;
The probe comes with a standard BNC output interface, compatible with oscilloscopes from any manufacturer (requires the oscilloscope input impedance to be set to 1MΩ;
When 50Ω is selected, the attenuation factor will be doubled), allowing measurement of the circuit under test waveforms;
Automatic save function to prevent repeated operations after power loss;
The probe has excellent common-mode noise suppression capabilities, with high input impedance and low capacitance at the input, allowing accurate and high-speed differential voltage measurement;
Can be widely used in the R&D, debugging, or maintenance of switching power supplies, frequency converters, electronic ballasts, variable frequency home appliances, and other electrical power devices.
——— Related Applications ———
——— Related Products ———
PMK FireFly®FF-1500A optically isolated probe 1.3 GHz/1.5 GHz high CMRR (180 dB) high-voltage 2500 V double-pulse VGS gate /VDS drain voltage
IWATSU multi-channel high-voltage high-frequency optically isolated measurement probe Isolation SE-6000 remote UHV safety test system
CIC high-voltage differential probe DP20-20K-LVC high-precision 0.1% high-frequency isolated high CMRR 20 kV
Model Number |
DP6070A |
||||
Bandwidth(-3dB) |
100 MHz |
||||
rise time |
≤3.5ns |
||||
Accuracy |
±2% |
||||
Range selection(attenuation ratio) |
10X/100X |
||||
|
Maximum differential measurement voltage (DC Peak AC) |
10X |
±70V |
|||
100X |
±700V |
||||
common-mode voltage(DC Peak AC) |
±700V |
||||
Maximum differential-mode voltageVS frequency curve |
Reference image1 |
||||
Maximum input-to-ground voltage (Vrms) |
450V CAT II 600V CATI |
||||
Input impedance |
Single-ended to ground |
2.5 MΩ |
|||
Between two input terminals |
5 MΩ |
||||
Input capacitance |
Single-ended to ground |
<4pF |
|||
Between two input terminals |
<2pF |
||||
CMRR |
DC |
>80dB |
|||
100 kHz |
>60dB |
||||
1 MHz |
>50dB |
||||
noise(Vrms) |
10X |
<20 mV |
|||
100X |
<120 mV |
||||
Overload indication voltage threshold |
10X |
≥70V |
|||
100X |
≥700V |
||||
Delay time |
Probe main unit |
9ns |
|||
BNC cable (1m) |
5ns |
||||
Bandwidth limit(5MHz) |
≥-3dB@5MHz |
||||
Overload Indicator Light(red light) |
there are |
||||
Overload audible alarm |
there are(Optional to turn off) |
||||
Auto-save function |
there are |
||||
Adjustable offset (bias) function |
Yes (adjustable in test mode) |
||||
Terminal load requirement |
≥100 kΩ |
||||
Power supplies |
USB 5V/1A adapter |
||||
Safety compliance standards |
EN61010-1: 2010 |
||||
EMCCompliance standards |
EN61326-1:2013 EN61000-3-2:2006 A1:2009 A2:2009 EN61000-3-3:2013 |
||||