The DP6000B series high-voltage differential probes are high-voltage differential probes with floating ground measurement capabilities. They have a maximum bandwidth of 300MHz, meeting the needs of most testing systems; they offer a wide range of scales to choose from, and their differential measurement voltage range meets the requirements of most test circuits; users can enter test mode to adjust the offset voltage, and if imbalance occurs after prolonged use, users can enter this mode to adjust the offset and achieve zeroing; electronic touch buttons provide longer service life; they feature a 5MHz bandwidth limit option, with the 5MHz bandwidth suited for measuring the switching frequency of FETs in most switching power supplies and can filter out higher frequency noise and interference; equipped with audible and visual alarm functions, with the option to manually turn off the sound alarm, making it more user-friendly; USB power interface, making it more convenient and flexible to use; the probe comes with a standard BNC output interface, compatible with oscilloscopes from any manufacturer (the oscilloscope input impedance must be set to 1MΩ; when 50Ω is selected, the attenuation factor will be halved) to measure waveforms of the circuit under test; automatic saving function prevents repeated operations after power loss. The probe has good common-mode noise suppression capability, with high input impedance and low capacitance at the input, enabling accurate and high-speed measurement of differential voltage signals. It can be widely used in the R&D, debugging, or maintenance of switching power supplies, inverters, electronic ballasts, variable frequency home appliances, and other electrical power devices.
——— Related Applications ———
——— Related Products ———
PMK FireFly®FF-1500A optically isolated probe 1.3 GHz/1.5 GHz high CMRR (180 dB) high-voltage 2500 V double-pulse VGS gate /VDS drain voltage
IWATSU multi-channel high-voltage high-frequency optically isolated measurement probe Isolation SE-6000 remote UHV safety test system
CIC high-voltage differential probe DP20-20K-LVC high-precision 0.1% high-frequency isolated high CMRR 20 kV
Electrical specifications
Model Number |
DP6070B |
||
Bandwidth(-3dB) |
300 MHz |
||
rise time |
≤1.16ns |
||
Accuracy |
±2% |
||
Range selection(attenuation ratio) |
20X/200X |
||
|
Maximum differential measurement voltage (DC Peak AC) |
20X |
±70V |
|
200X |
±700V |
||
common-mode voltage(DC Peak AC) |
±700V |
||
Maximum differential-mode voltageVS frequency curve |
Reference image1 |
||
Maximum input-to-ground voltage (Vrms) |
450V CAT II 600V CATI |
||
Input impedance |
Single-ended to ground |
2.5 MΩ |
|
Between two input terminals |
5 MΩ |
||
Input capacitance |
Single-ended to ground |
<4pF |
|
Between two input terminals |
<2pF |
||
CMRR |
DC |
>80dB |
|
100 kHz |
>60dB |
||
1 MHz |
>50dB |
||
noise(Vrms) |
20X |
<90mV |
|
200X |
<120 mV |
||
Overload indication voltage threshold |
20X |
≥70V |
|
200X |
≥700V |
||
Delay time |
Probe main unit |
6ns |
|
BNC cable (1m) |
5ns |
||
Bandwidth limit(5MHz) |
≥-3dB@5MHz |
||
Overload Indicator Light(red light) |
there are |
||
Overload audible alarm |
there are(Optional to turn off) |
||
Auto-save function |
there are |
||
Adjustable offset (bias) function |
Yes (adjustable in test mode) |
||
Terminal load requirement |
≥100 kΩ |
||
Power supplies |
USB 5V/2A Adapter |
||
Safety compliance standards |
EN61010-1: 2010 |
||
EMCCompliance standards |
EN61326-1:2013 EN61000-3-2:2006 A1:2009 A2:2009 EN61000-3-3:2013 |
||