Cybertek
Categories
Probemart.com | Probes, current sensors & calibration sources for pulsed-power testing
Bookmark
Cybertek
Categories

The DP6000D series high-voltage differential probes are high-voltage differential probes with floating ground measurement capability. They feature a high bandwidth of up to 500MHz, meeting the needs of most testing systems; a wide range of selectable measurement ranges, with differential measurement voltage ranges suitable for most test circuits; users can enter the test mode to adjust the offset voltage, and if imbalance occurs after long-term use, users can enter this mode to adjust the offset to achieve zeroing; electronic touch buttons provide longer service life; a 5MHz bandwidth limit function is available, and the 5MHz frequency bandwidth meets the measurement requirements of most switching frequency FETs in power supplies and can filter out higher-frequency noise and interference; it has audio-visual alarm functions, with the option to manually turn off the sound alarm, providing more user-friendly design; USB power interface makes it more convenient and flexible to use; the probe is equipped with a standard BNC output interface and can be used with oscilloscopes from any manufacturer (requiring the oscilloscope input impedance to be set to 50Ω (preferably using the oscilloscope’s internal 50Ω), or connected to the standard through-type 50Ω load with the oscilloscope input impedance set to 1MΩ) for measuring the waveform of the tested circuit; automatic save function prevents users from repeating operations after power loss. The probe has excellent common-mode noise suppression, with high input impedance and low capacitance at the input, allowing accurate and high-speed differential voltage measurements. It can be widely used in the research, debugging, or maintenance of switching power supplies, inverters, electronic ballasts, variable frequency home appliances, and other electrical power devices.
——— Related Applications ———
——— Related Products ———
PMK FireFly®FF-1500A optically isolated probe 1.3 GHz/1.5 GHz high CMRR (180 dB) high-voltage 2500 V double-pulse VGS gate /VDS drain voltage
IWATSU multi-channel high-voltage high-frequency optically isolated measurement probe Isolation SE-6000 remote UHV safety test system
CIC high-voltage differential probe DP20-20K-LVC high-precision 0.1% high-frequency isolated high CMRR 20 kV
Electrical specifications
Model Number |
DP6150D |
||
Bandwidth(-3dB) |
500 MHz |
||
rise time |
≤700ps |
||
Accuracy |
±2% |
||
Range selection(attenuation ratio) |
100X/1000X |
||
|
Maximum differential measurement voltage (DC Peak AC) |
100X |
±150V |
|
1000X |
±1500V |
||
common-mode voltage(DC Peak AC) |
±1500V |
||
Maximum differential-mode voltageVS frequency curve |
Reference image2 |
||
Maximum input-to-ground voltage (Vrms) |
600V CAT III 1000V CAT II |
||
Input impedance |
Single-ended to ground |
5 MΩ |
|
Between two input terminals |
10 MΩ |
||
Input capacitance |
Single-ended to ground |
<4pF |
|
Between two input terminals |
<2pF |
||
CMRR |
DC |
>80dB |
|
100 kHz |
>60dB |
||
1 MHz |
>50dB |
||
noise(Vrms) |
100X |
<200 mV |
|
1000X |
<400 mV |
||
Overload indication voltage threshold |
100X |
≥150V |
|
1000X |
≥1500V |
||
Delay time |
Probe main unit |
6 ns |
|
BNC cable (1m) |
5ns |
||
Bandwidth limit(5MHz) |
≥-3dB@5MHz |
||
Overload Indicator Light(red light) |
there are |
||
Overload audible alarm |
there are(Optional to turn off) |
||
Auto-save function |
there are |
||
Adjustable offset (bias) function |
Yes (adjustable in test mode) |
||
Terminal load requirement |
50Ω |
||
Power supplies |
USB 5V/2A Adapter |
||
Safety compliance standards |
EN61010-1: 2010 |
||
EMCCompliance standards |
EN61326-1:2013 EN61000-3-2:2006 A1:2009 A2:2009 EN61000-3-3:2013 |
||