Cybertek
Categories
Probemart.com | Probes, current sensors & calibration sources for pulsed-power testing
Bookmark
Cybertek
Categories

The DP6000A series high-voltage differential probes are high-voltage differential probes with floating ground measurement capabilities. They have a maximum bandwidth of 100MHz, meeting the needs of most testing systems; they offer a variety of measurement ranges, and their differential voltage measurement range satisfies the requirements of most test circuits. Users can enter a test mode to adjust the offset voltage; if the probe becomes unbalanced after prolonged use, users can enter this mode to adjust the offset and achieve zeroing. The electronic touch button extends the service life of the probe. It features a 5MHz bandwidth limit option; the 5MHz frequency bandwidth meets the measurement requirements of the switching frequency of most FETs in switching power supplies and can filter out higher frequency noise and interference. It is equipped with audio-visual alarm functionality, which can be manually disabled, making it more user-friendly. The USB power interface makes it more convenient and flexible to use. The probe comes with a standard BNC output interface and can be used with oscilloscopes from any manufacturer (the oscilloscope input impedance should be set to 1MΩ; if 50Ω is selected, the attenuation factor will be halved) to measure the waveform of the circuit under test. It has an auto-save function to prevent users from repeated operations after a power outage. The probe has good common-mode noise suppression capability, a high input impedance, and low capacitance at the input, allowing accurate and high-speed measurement of differential voltage signals. It can be widely used in the research, debugging, or maintenance of switching power supplies, inverters, electronic ballasts, variable-frequency home appliances, and other electrical power devices.
——— Related Applications ———
——— Related Products ———
PMK FireFly®FF-1500A optically isolated probe 1.3 GHz/1.5 GHz high CMRR (180 dB) high-voltage 2500 V double-pulse VGS gate /VDS drain voltage
IWATSU multi-channel high-voltage high-frequency optically isolated measurement probe Isolation SE-6000 remote UHV safety test system
CIC high-voltage differential probe DP20-20K-LVC high-precision 0.1% high-frequency isolated high CMRR 20 kV
Electrical specifications
Model Number |
DP6350A |
||
Bandwidth(-3dB) |
100 MHz |
||
rise time |
≤3.5ns |
||
Accuracy |
±2% |
||
Range selection(attenuation ratio) |
100X/1000X |
||
|
Maximum differential measurement voltage (DC Peak AC) |
100X |
±350V |
|
1000X |
±3500V |
||
common-mode voltage(DC Peak AC) |
±3500V |
||
Maximum differential-mode voltageVS frequency curve |
Reference image3 |
||
Maximum input-to-ground voltage (Vrms) |
600V CAT III 1000V CAT II |
||
Input impedance |
Single-ended to ground |
5 MΩ |
|
Between two input terminals |
10 MΩ |
||
Input capacitance |
Single-ended to ground |
<4pF |
|
Between two input terminals |
<2pF |
||
CMRR |
DC |
>80dB |
|
100 kHz |
>60dB |
||
1 MHz |
>50dB |
||
noise(Vrms) |
100X |
<100mV |
|
1000X |
<600mV |
||
Overload indication voltage threshold |
100X |
≥350V |
|
1000X |
≥3500V |
||
Delay time |
Probe main unit |
9ns |
|
BNC cable (1m) |
5ns |
||
Bandwidth limit(5MHz) |
≥-3dB@5MHz |
||
Overload Indicator Light(red light) |
there are |
||
Overload audible alarm |
there are(Optional to turn off) |
||
Auto-save function |
there are |
||
Adjustable offset (bias) function |
Yes (adjustable in test mode) |
||
Terminal load requirement |
≥100 kΩ |
||
Power supplies |
USB 5V/2A Adapter |
||
Safety compliance standards |
EN61010-1: 2010 |
||
EMCCompliance standards |
EN61326-1:2013 EN61000-3-2:2006 A1:2009 A2:2009 EN61000-3-3:2013 |
||