Cybertek
Categories
Probemart.com | Probes, current sensors & calibration sources for pulsed-power testing
Bookmark
Cybertek
Categories

Brand: Cybertek
Origin: China
The HCP8000 series current probes are high-frequency current probes capable of measuring both direct current (DC) and alternating current (AC).
Main Features of the HCP8000 Series:
High bandwidth to accurately and quickly capture current waveforms;
High accuracy, with up to 1% precision within the current measurement range, meeting the needs of most testing fields;
Two ranges available for easy measurement of small currents;
Automatic demagnetization and zero adjustment function for convenient use;
Audible and visual over-current alarm function to indicate range switching;
Electronic touch key design for longer service life;
Standard BNC output interface, compatible with oscilloscopes from any manufacturer.
The HCP8030 is compact and can be easily used on crowded circuit boards;
The small clamp can probe currents in tight spaces while still clamping wires up to 5mm in diameter;
It can measure 30A of continuous current and 50A of peak current, with the HCP8030 offering a 50MHz bandwidth;
The probe offers two ranges: 30A (10X) and 5A (1X); the 5A (1X) range is especially suitable for measuring small currents, with a resolution of up to 1mA.
——— Related Applications ———
——— Related Products ———
PMK FireFly®FF-1500A optically isolated probe 1.3 GHz/1.5 GHz high CMRR (180 dB) high-voltage 2500 V double-pulse VGS gate /VDS drain voltage
IWATSU multi-channel high-voltage high-frequency optically isolated measurement probe Isolation SE-6000 remote UHV safety test system
CIC high-voltage differential probe DP20-20K-LVC high-precision 0.1% high-frequency isolated high CMRR 20 kV
Model No. |
HCP8030 |
||
Bandwidth(-3dB) |
DC-50MHz (Figure1.a) |
||
rise time |
≤7ns |
||
|
Continuous current Maximum value |
30Arms Figure 2.a |
||
Peak current |
50Apk |
||
Range |
5A |
1X Attenuation |
|
30A |
10X attenuation |
||
Overcurrent Alarm Value |
5A |
≥5A |
|
30A |
≥50A |
||
Current transmission ratio |
5A |
1V/A |
|
30A |
0.1V/A |
||
resolution |
5A |
1mA |
|
30A |
10mA |
||
|
Accuracy (DC, 45-66Hz)Maximum continuous current) |
5A |
±1%±1 mA |
|
30A |
±1%±10mA |
||
Input impedance |
Refer to Figure 3.a |
||
|
Delay time |
probe Host |
14 ns |
|
|
BNC (1m) |
5ns |
||
Terminal load requirement |
≥100 kΩ |
||
Power supply method |
DC 12V/1A(Standard adapter) |
||
Insulated wire voltage |
300V CATI |
||
Safety compliance standards |
EN61010-1: 2010 A1:2019 EN 61010-2-032:2019 |
||
EMC compliance standards |