The HCP8000 series current probes are high-frequency current probes capable of measuring both DC and AC currents.
Main features of the HCP8000 series:
High bandwidth, accurately and quickly capturing current waveforms;
High precision, within the range of current measurement, the accuracy is up to 1%, meeting the needs of most testing fields;
Two measurement ranges are available, convenient for measuring small currents;
Automatic demagnetization and zeroing function for ease of use;
Audible and visual overcurrent alarm function to indicate range switching;
Electronic touch-button design for longer service life; standard BNC output interface, compatible with oscilloscopes from any manufacturer.
The HCP8050 clamp can hold wires up to 5mm in diameter; it can measure 50A of continuous current and 75A of peak current, providing a 50MHz bandwidth; the probe has two range options, 50A (10X) and 7.5A (1X), with the 7.5A (1X) range being especially suitable for small current measurements, offering a resolution of up to 1mA.
——— Related Applications ———
——— Related Products ———
PMK FireFly®FF-1500A optically isolated probe 1.3 GHz/1.5 GHz high CMRR (180 dB) high-voltage 2500 V double-pulse VGS gate /VDS drain voltage
IWATSU multi-channel high-voltage high-frequency optically isolated measurement probe Isolation SE-6000 remote UHV safety test system
CIC high-voltage differential probe DP20-20K-LVC high-precision 0.1% high-frequency isolated high CMRR 20 kV
Model No. |
HCP8050 |
||
Bandwidth(-3dB) |
DC-50MHz (Figure4) |
||
rise time |
≤7ns |
||
Continuous currentMaximum value |
50Arms (Figure5) |
||
Peak current |
75Apk |
||
Range |
7.5A |
1Xattenuation |
|
50A |
10Xattenuation |
||
Overcurrent Alarm Value |
7.5A |
≥7.5A |
|
50A |
≥75A |
||
Current transmission ratio |
7.5A |
1V/A |
|
50A |
0.1 V/A |
||
resolution |
7.5A |
1 mA |
|
50A |
10mA |
||
|
Accuracy (DC, 45-66Hz)Maximum continuous current) |
7.5A |
±1%±1 mA |
|
50A |
±1%±10mA |
||
Input impedance |
Reference(Figure6) |
||
|
Delay time |
probe Host |
14 ns |
|
|
BNC (1m) |
5ns |
||
Terminal load requirement |
≥100 kΩ |
||
Power supply method |
DC 12V/1A(Standard adapter) |
||
Insulated wire voltage |
300V CAT I |
||
Safety compliance standards |
EN61010-1: 2010 A1:2019 EN 61010-2-032:2019 |
||
EMCCompliance standards |
EN61326-1:2013 EN61000-3-2:2014 EN61000-3-3:2013 |
||