Cybertek
Categories
Probemart.com | Probes, current sensors & calibration sources for pulsed-power testing
Bookmark
Cybertek
Categories

Brand: Cybertek
Origin: China
The HCP8000 series current probes are high-frequency current probes capable of measuring both DC and AC currents.
Main features of the HCP8000 series:
High bandwidth, accurately and quickly capturing current waveforms;
High precision, with accuracy up to 1% within the current measurement range, meeting the needs of most testing fields;
Two measurement ranges available, convenient for measuring small currents;
Automatic demagnetization and zeroing function, easy to use;
Acoustic and visual overcurrent alarm to indicate range switching;
Electronic touch button design, longer service life; standard BNC output interface, compatible with oscilloscopes from any manufacturer.
The HCP8300 clamp can hold conductors up to 20mm in diameter, suitable for high-current applications;
Measures 300A continuous current and 500A peak current, providing 6MHz bandwidth;
The probe offers two ranges, 300A (100X) and 50A (10X), with the 10X range for small current measurement providing resolution up to 10mA.
The HCP8000 series current probes are commonly used in the design and testing of switch-mode power supplies, motor drivers, electronic ballasts, LED lighting, and new energy applications.
——— Related Applications ———
——— Related Products ———
PMK FireFly®FF-1500A optically isolated probe 1.3 GHz/1.5 GHz high CMRR (180 dB) high-voltage 2500 V double-pulse VGS gate /VDS drain voltage
IWATSU multi-channel high-voltage high-frequency optically isolated measurement probe Isolation SE-6000 remote UHV safety test system
CIC high-voltage differential probe DP20-20K-LVC high-precision 0.1% high-frequency isolated high CMRR 20 kV
Model No. |
HCP8300 |
||
Bandwidth(-3dB) |
DC-6MHz (Figure10) |
||
rise time |
≤58ns |
||
|
Continuous current Maximum value |
300Arms (Figure11) |
||
Peak current |
500Apk |
||
Range |
50A |
10Xattenuation |
|
300A |
100Xattenuation |
||
Overcurrent Alarm Value |
50A |
≥50A |
|
300A |
≥500A |
||
Current transmission ratio |
50A |
0.1V/A |
|
300A |
0.01V/A |
||
resolution |
50A |
10mA |
|
300A |
100mA |
||
|
Accuracy (DC, 45-66Hz)Maximum continuous current) |
50A |
±1%±10mA |
|
300A |
±1%±100mA |
||
Input impedance |
Reference(Figure12) |
||
|
Delay time |
probeHost |
41 ns |
|
BNC(1 meter) |
5ns |
||
Terminal load requirement |
≥100 kΩ |
||
Power supply method |
DC 12V/1A(Standard adapter) |
||
Insulated wire voltage |
600V CAT II 300V CAT III |
||
Safety compliance standards |
EN61010-1: 2010 A1:2019 EN 61010-2-032:2019 |
||
EMCCompliance standards |