Danisense
Categories
Probemart.com | Probes, current sensors & calibration sources for pulsed-power testing
Bookmark
Danisense
Categories

DANISENSE Fluxgate Current Sensor DCCT currents sensor Products selection guide 2022.8v0-en.pdf
Danisense Fluxgate Sensor DS50ID Datasheet.pdf
Danisense Fluxgate Sensor DS200ID Datasheet.pdf
Danisense Fluxgate Sensor DS300ID Datasheet.pdf
Danisense Fluxgate Sensor DS400ID Datasheet.pdf
Danisense Fluxgate Sensor DS600ID Datasheet.pdf
Danisense Fluxgate Sensor DS50UB-1V Datasheet.pdf
Danisense Fluxgate Sensor DS50UB-10V Datasheet.pdf
Danisense Fluxgate Sensor DS200UB-1V Datasheet.pdf
Danisense Fluxgate Sensor DS200UB-10V Datasheet.pdf
Danisense Fluxgate Sensor DS300UB-1V Datasheet.pdf
Danisense Fluxgate Sensor DS300UB-10V Datasheet.pdf
Danisense Fluxgate Sensor DS400UB-1V Datasheet.pdf
Danisense Fluxgate Sensor DS400UB-10V Datasheet.pdf
Danisense Fluxgate Sensor DS600UB-1V Datasheet.pdf
Danisense Fluxgate Sensor DS600UB-10V Datasheet.pdf
Danisense Fluxgate Sensor DS1000UB-10V Datasheet.pdf
Danisense Fluxgate Sensor DT50ID-4 Datasheet.pdf
Danisense Fluxgate Sensor DT100ID-5 Datasheet.pdf
Danisense Fluxgate Sensor DT200ID-5 Datasheet.pdf
Danisense Fluxgate Sensor DL2000ID Datasheet.pdf
Danisense Fluxgate Sensor DL2000UB-1V Datasheet.pdf
Danisense Fluxgate Sensor DL2000UB-10V Datasheet.pdf
Danisense Fluxgate Sensor DM1200ID-CD3000 Datasheet.pdf
Danisense Fluxgate Sensor DM1200ID Datasheet.pdf
Danisense Fluxgate Sensor DM1200UB-1V Datasheet.pdf
Danisense Fluxgate Sensor DM1200UB-10V Datasheet.pdf
Danisense Fluxgate Sensor DQ500ID Datasheet.pdf
Danisense Fluxgate Sensor DQ600ID Datasheet.pdf
Danisense Fluxgate Sensor DR5000IM Datasheet.pdf
Danisense Fluxgate Sensor DR5000UX-10V_5000A Datasheet.pdf
Danisense Fluxgate Sensor DR5000UX-10V_7500A Datasheet.pdf
Danisense Fluxgate Sensor DR10000IM Datasheet.pdf
Danisense Fluxgate Current Probe Product Manual DS_Product_Manual-Probemart.pdf
Danisense Fluxgate DSSIU-6 How-to-modify-a-DSSIU-6-from-voltage-to-current.pdf
Danisense Overview RCM-by-Danisense.pdf
Danisense Fluxgate Current Probe Selection Guide (Probemart)Products selection guide 2022.8v0-en.pdf
Danisense Current Sensor Principle - Probemart.pdf
brand Danisense originates from Denmark. The Danisense DS series current sensors are based on zero flux gate sensor technology.
has a nonlinear error of 1 ppm and is widely used in MRI, particle accelerators, and high-precision power analysis.
The Danisense DS series current sensors are closed-loop zero flux gate sensor technology based on nonlinear flux detection elements.
They offer ultra-high measurement accuracy and can be used for high-precision DC current measurement, power and energy performance analysis.
flux gate sensors measure weak magnetic fields by utilizing the nonlinear relationship between the magnetic induction strength and magnetic field strength of the high-permeability magnetic core under alternating magnetic field saturation excitation. This physical phenomenon acts like a "gate" to the measured environmental magnetic field; through this "gate," the corresponding magnetic flux is modulated and induced electromotive force. This phenomenon is used to measure the magnetic field generated by the current, thereby indirectly achieving current measurement. The flux gate sensor is based on the nonlinear magnetization characteristics of the iron core material. Its sensitive components are made of high magnetic permeability, easily saturated materials, with two windings surrounding the core: one is the excitation coil and the other is the signal coil. Under the magnetization of the alternating excitation signal fl, the magnetic conductivity of the iron core undergoes periodic changes between saturation and unsaturation, causing the induction coil surrounding the core to induce signals that respond to the external magnetic field. Danisense is the industry benchmark for flux gate sensors. The high-tech Chinese company Hangzhi Technology uses multi-point zero flux patented technology and is a leading global brand in high-precision current measurement.
Advantages and features of Danisense magnetic flux gates:
metrology-grade accuracy (up to 1ppm)
low zero drift
Multiple signal interfaces available
extremely low flux switching noise
stronger static electricity and shielding effect, better suppressing dV/dt coupling
ultra-high temperature stability: -40~+85°
wider current testing range: up to 10KA RMS
Typical application
of fluxgate current transformers
Medical MRI High-precision current or power measurement
data center DC power supply system
AC/DC current calibration
large-scale shipboard power systems
solar photovoltaics, wind energy storage systems
energy storage and charging
for new energy vehicles metering and standards
——— Related Applications ———
——— Related Products ———
PMK FireFly®FF-1500A optically isolated probe 1.3 GHz/1.5 GHz high CMRR (180 dB) high-voltage 2500 V double-pulse VGS gate /VDS drain voltage
IWATSU multi-channel high-voltage high-frequency optically isolated measurement probe Isolation SE-6000 remote UHV safety test system
CIC high-voltage differential probe DP20-20K-LVC high-precision 0.1% high-frequency isolated high CMRR 20 kV
Click the model link to view datasheet
| Danisensecurrent sensor0~1000A: | ||||||
| Model (0-1KA) | Manual | Current range | Product Dimensions (mm) | Aperture (mm) | Transformation ratio | Output port |
| Faston connection | ||||||
| 300A | 80×61.5×41.5 | 20 | 1:1000 | Faston | ||
| DSUB current output type | ||||||
| 150A | 121.4×107.5×44.5 | 27.6 | 1:500 | DSUB9 | ||
| 370A | 121.4×107.5×44.5 | 27.6 | 1:500 | DSUB9 | ||
| 500A | 121.4×107.5×44.5 | 27.6 | 1:1000 | DSUB9 | ||
| 600A | 121.4×107.5×44.5 | 27.6 | 1:2000 | DSUB9 | ||
| 1000A | 121.4×107.5×44.5 | 27.6 | 1:1500 | DSUB9 | ||
| 800A | 104×106×47 | 28.1 | 1:1750 | DSUB9 | ||
| 1000A | 104×106×47 | 28.1 | 1:1500 | DSUB9 | ||
| DQ640ID-B | 640A | 104×106×47 | 28.1 | 40A-640A | DSUB9 | |
| 1300A | 104×106×47 | 28.1 | 1:1500 | DSUB9 | ||
| BNC voltage output type | ||||||
| 150A | 121.4×107.5×44.5 | 27.6 | 1V:50A | DSUB9/BNC | ||
| 55A | 121.4×107.5×44.5 | 27.6 | 10V:50A | DSUB9/BNC | ||
| 300A | 121.4×107.5×44.5 | 27.6 | 1V:200A | DSUB9/BNC | ||
| 220A | 121.4×107.5×44.5 | 27.6 | 10V:200A | DSUB9/BNC | ||
| 500A | 121.4×107.5×44.5 | 27.6 | 1V:300A | DSUB9/BNC | ||
| 330A | 121.4×107.5×44.5 | 27.6 | 10V:300A | DSUB9/BNC | ||
| 600A | 121.4×107.5×44.5 | 27.6 | 1V:400A | DSUB9/BNC | ||
| 440A | 121.4×107.5×44.5 | 27.6 | 10V:400A | DSUB9/BNC | ||
| 900A | 121.4×107.5×44.5 | 27.6 | 1V:600A | DSUB9/BNC | ||
| 660A | 121.4×107.5×44.5 | 27.6 | 10V:600A | DSUB9/BNC | ||
| 1100A | 121.4×107.5×44.5 | 27.6 | 10V:1000A | DSUB9/BNC | ||
| BNC voltage output type | ||||||
| DS200ID-CD100 | 370A | 121.4×107.5×44.5 | 27.6 | 1:500 | DSUB9 | |
| DS200ID-CD1000 | 370A | 121.4×107.5×44.5 | 27.6 | 1:500 | DSUB9 | |
| DS600ID-CD100 | 1000A | 121.4×107.5×44.5 | 27.6 | 1:1500 | DSUB9 | |
| Danisensecurrent sensor1000–3000A: | ||||||
| Model (1-3KA) | Manual | Current range | Product Dimensions (mm) | Aperture (mm) | Transformation ratio | Output port |
| DSUB current output | ||||||
| 1800A | 178.6×174×53 | 45 | 1:500 | DSUB9 | ||
| 3000A | 239.8×230×82 | 68 | 1:500 | DSUB9 | ||
| BNC voltage output (2ppm/k) | ||||||
| 1800A | 178.6×174×53 | 45 | 1V:2000A | DSUB9/BNC | ||
| 1320A | 178.6×174×53 | 45 | 10V:2000A | DSUB9/BNC | ||
| 3000A | 239.8×230×82 | 68 | 1V:2000A | DSUB9/BNC | ||
| 3000A | 239.8×230×82 | 68 | 10V:2000A | DSUB9/BNC | ||
| Calibration winding BNC | ||||||
| DL2000ID-CB100 | 3000A | 239.8×230×82 | 68 | 1:500 | DSUB9/BNC | |
| Calibration winding DSUB | ||||||
| DL2000ID-CD100 | 3000A | 239.8×230×82 | 68 | 1:500 | DSUB9 | |
| Danisensecurrent sensorAbove 3000A: | ||||||
| Model (0-1KA) | Manual | Current range | Product Dimensions (mm) | Aperture (mm) | Transformation ratio | Output port |
| Current output | ||||||
| 8000A | 420×325×122 | 150 | 1:2500 | 4mm banana head | ||
| 11000A | 420×325×122 | 140 | 1:2500 | 4mm banana head | ||
| DSUB current output type | ||||||
| 550 | 420×325×122 | 150 | 1V:50A | 3-pin XLR Mini | ||
| 8000A | 420×325×122 | 150 | 1.333V:KA | 3-pin XLR Mini | ||
| DR5000UX-10V | 11000A | 420×325×122 | 140 | 1V:1KA | 3-pin XLR Mini | |