IWATSU
Categories
Probemart.com | Probes, current sensors & calibration sources for pulsed-power testing
Bookmark
IWATSU
Categories

IWATSUIWATSU Rogowski Coil Rogowski Datasheet datasheet.pdf
PD-200X Overview (V2.0).pdf
IWATSU rogowski IWATSU Rogowski Current Probe SS-280A Manual -Probemart.pdf
IWATSUIWATSU Rogowski Coil Rogowski Datasheet datasheet.pdf
IWATSU Rogowski Coil User Guide.pdf
IWATSU Current Probe Current Probe ?-Probemart.pdf
IWATSU Technical Material Rogowski Coil _ -Probemart.pdf
IWATSU Rogowski Coil Signal Droop Characteristics _ Technical Material _ -Probemart.pdf
IWATSU Application Article Rogowski Coil Overview -Probemart.pdf
IWATSU Application Article Rogowski Current Probe Principle -Probemart.pdf
Wide-Bandgap Device Dynamic Characterization iV1.03_2023_jectronic.pdf
The SS-280AH series uses an open-type flexible coil with a maximum wire diameter of 1.7mm, which can pass through pin tests, suitable for narrow and extremely small spaces. The coil length is 84mm. Compared with traditional current sensors, it is easier to install and use, allowing for online current measurement and monitoring.
The SS-280A-H series has an appearance basically identical to the SS-280A series and similar measurement ranges. The main difference is that the SS-280A-H series is resistant to high temperatures up to 150°C.
It is the only Rogowski coil that can withstand temperatures above 125°C.
————————————————————————————————————————————————————
Main Features of the SS-280A-H Series:
The tip of the probe is as thin as 1.7mm in diameter, capable of directly probing TO-type MOSFETs and IGBTs used in power electronics equipment such as switched-mode power supplies.
Frequency bandwidth of 30MHz allows observation of high-frequency switching waveforms.
Current measurement range from 30A to 30,000A supports a variety of current measurements. Since it does not experience magnetic saturation, it can safely measure large currents.
Probe applicable temperature range (A-H type temperature range)-40°C ~ 150°C
——— Related Applications ———
——— Related Products ———
PMK FireFly®FF-1500A optically isolated probe 1.3 GHz/1.5 GHz high CMRR (180 dB) high-voltage 2500 V double-pulse VGS gate /VDS drain voltage
IWATSU multi-channel high-voltage high-frequency optically isolated measurement probe Isolation SE-6000 remote UHV safety test system
CIC high-voltage differential probe DP20-20K-LVC high-precision 0.1% high-frequency isolated high CMRR 20 kV
| Parameter | Value |
|---|---|
| Peak Current | 600 A |
| High Frequency Bandwidth | 30 MHz |
| Low Frequency Cut-off | 6 Hz |
| Frequency Bandwidth | 6 Hz~30 MHz |
| Peak di/dt | 40 kA/µs |
| Sensitivity | 10 mV/A |
| Typical Accuracy | ±2% |
| Noise | 1.8 mV (rms, effective value) |
| Coil Withstand Voltage | 1.2 kV |
| Operating Temperature | -40~+150 °C |
| Zero Adjustment | Yes |
| Coil Diameter | Max 1.7 mm |
| Coil Length | 84±4 mm |
| Cable Length | 1.5 m |