IWATSU
Categories
Probemart.com | Probes, current sensors & calibration sources for pulsed-power testing
Bookmark
IWATSU
Categories

IWATSU rogowski IWATSU Rogowski Current Probe SS-290 Manual -Probemart.pdf
IWATSUIWATSU Rogowski Coil Rogowski Datasheet datasheet.pdf
IWATSU Rogowski Coil User Guide.pdf
IWATSU Current Probe Current Probe ?-Probemart.pdf
IWATSU Technical Material Rogowski Coil _ -Probemart.pdf
IWATSU Rogowski Coil Signal Droop Characteristics _ Technical Material _ -Probemart.pdf
IWATSU Application Article Rogowski Coil Overview -Probemart.pdf
IWATSU Application Article Rogowski Current Probe Principle -Probemart.pdf
Wide-Bandgap Device Dynamic Characterization iV1.03_2023_jectronic.pdf
The IWATSU SS-290 AC current probe is a practical conversion tool designed to solve your power electronics current measurement problems:
With high bandwidth and a large measurement range, combined with high-quality measurement specifications, it ensures your measurement requirements are met;
The thin, flexible induction loop allows you to easily connect to the actual measurement object.
Main features of the SS-290 series:
The probe's top coil has a diameter of 8.5mm, and the open-type coil poses no risk of opening the measured circuit.
With a frequency bandwidth of 20MHz, high-frequency switching waveforms can be observed.
The current measurement range of 1200A~120000A supports various current measurements, and because it does not experience magnetic saturation, large current measurements can be performed safely.
The probe operates in a temperature range of -40°C~125°C.
Withstands voltage up to 10KV.
——— Related Applications ———
——— Related Products ———
PMK FireFly®FF-1500A optically isolated probe 1.3 GHz/1.5 GHz high CMRR (180 dB) high-voltage 2500 V double-pulse VGS gate /VDS drain voltage
IWATSU multi-channel high-voltage high-frequency optically isolated measurement probe Isolation SE-6000 remote UHV safety test system
CIC high-voltage differential probe DP20-20K-LVC high-precision 0.1% high-frequency isolated high CMRR 20 kV
| Model | Peak Current (A) | High Frequency Bandwidth (MHz) | Low Frequency Cut-off (Hz) | Frequency Bandwidth | Sensitivity (mV/A) | Typical Accuracy (%) | Noise (mV) | Coil Withstand Voltage (kV) | Operating Temperature (°C) | Zero Adjustment | Coil Diameter (mm) | Coil Length (mm) | Cable Length (m) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| SS-295S | 6000 A | 20 MHz | 0.6 Hz | 0.6 Hz~20 MHz | 1 mV/A | ±2% | 1.4 mV (rms, effective value) | 10 kV | -40~+125 °C | Yes | 8.5 mm | 300 mm | 3.0 m |
| SS-295M | 6000 A | 15 MHz | 0.6 Hz | 0.6 Hz~15 MHz | 1 mV/A | ±2% | 1.4 mV (rms, effective value) | 10 kV | -40~+125 °C | Yes | 8.5 mm | 500 mm | 3.0 m |
| SS-295L | 6000 A | 10 MHz | 0.6 Hz | 0.6 Hz~10 MHz | 1 mV/A | ±2% | 1.4 mV (rms, effective value) | 10 kV | -40~+125 °C | Yes | 8.5 mm | 700 mm | 3.0 m |
| SS-295XL | 6000 A | 5 MHz | 0.6 Hz | 0.6 Hz~5 MHz | 1 mV/A | ±2% | 1.4 mV (rms, effective value) | 10 kV | -40~+125 °C | Yes | 8.5 mm | 1100 mm | 3.0 m |
Note: Noise values are mV rms (effective value)