IWATSUIWATSU Rogowski Coil Rogowski Datasheet datasheet.pdf
IWATSU rogowski IWATSU Rogowski Current Probe SS-620 Manual -Probemart.pdf
IWATSUIWATSU Rogowski Coil Rogowski Datasheet datasheet.pdf
IWATSU Rogowski Coil User Guide.pdf
IWATSU Current Probe Current Probe ?-Probemart.pdf
IWATSU Technical Material Rogowski Coil _ -Probemart.pdf
IWATSU Rogowski Coil Signal Droop Characteristics _ Technical Material _ -Probemart.pdf
IWATSU Application Article Rogowski Coil Overview -Probemart.pdf
IWATSU Application Article Rogowski Current Probe Principle -Probemart.pdf
Wide-Bandgap Device Dynamic Characterization iV1.03_2023_jectronic.pdf
IWATSU Iwasaki SS-620 series open-type flexible coils, suitable for narrow measurement environments, 3mm wire diameter, 10~25MHz.
High frequency and high voltage tolerance, high current, small size Rogowski coils, can replace PEM CWT Mini series
Main features of the SS-620 series:
The probe top coil diameter is as thin as 3mm. Although it is a flexible sensing coil, it has a high voltage tolerance of 5KV.
Current measurement range is 60A~30000A, supporting various current measurements.
Since it does not magnetically saturate, it can safely measure high currents.
Four coil lengths are available (100/200/300/500mm)
——— Related Applications ———
——— Related Products ———
PMK FireFly®FF-1500A optically isolated probe 1.3 GHz/1.5 GHz high CMRR (180 dB) high-voltage 2500 V double-pulse VGS gate /VDS drain voltage
IWATSU multi-channel high-voltage high-frequency optically isolated measurement probe Isolation SE-6000 remote UHV safety test system
CIC high-voltage differential probe DP20-20K-LVC high-precision 0.1% high-frequency isolated high CMRR 20 kV
| Parameter | Value |
|---|---|
| Peak Current | 6000 A |
| High Frequency Bandwidth | 25 MHz |
| Low Frequency Cut-off | 0.6 Hz |
| Frequency Bandwidth | 0.6 Hz~25 MHz |
| Peak di/dt | 80 kA/µs |
| Sensitivity | 1 mV/A |
| Typical Accuracy | ±2% |
| Noise | 1.4 mV (rms, effective value) |
| Coil Withstand Voltage | 5 kV |
| Operating Temperature | -40~+125 °C |
| Zero Adjustment | Yes |
| Coil Diameter | 3.0 mm |
| Coil Length | 100 mm |
| Cable Length | 3.0 m |