Product Features:
Easy to modify, easy to install in space-limited applications, non-intrusive—no need to draw power from the main circuit, wide bandwidth up to 1MHz,
Used to measure harmonic components or complex waveforms (such as induction heating, VF drive, power measurement)
The size of the Rogowski coil can be specified independently of the primary current.
Will not happenmagnetic saturation
Intrinsic Safety
Equivalent to Class 1 current transformer or better, suitable for low-cost monitoring of medium/high currents.
——— Related Applications ———
——— Related Products ———
PMK FireFly®FF-1500A optically isolated probe 1.3 GHz/1.5 GHz high CMRR (180 dB) high-voltage 2500 V double-pulse VGS gate /VDS drain voltage
IWATSU multi-channel high-voltage high-frequency optically isolated measurement probe Isolation SE-6000 remote UHV safety test system
CIC high-voltage differential probe DP20-20K-LVC high-precision 0.1% high-frequency isolated high CMRR 20 kV
| Parameter Item | Specifications |
|---|---|
| rated current (rms) | 250A, 500A, 800A, 1000A, 1600A, 2000A2500A, 3000A, 4000A, 5000A, 8000A, 10000A16000A, 20000A, 25000A, 30000A, 40000A, 50000A |
| Rated Output (Full Scale FS) | 5.0Vrms (±7.07V peak value) |
| Output limit | 150% FS (±10.6V peak value) |
| Power Supply Voltage (Wide Input) | 12Vdc (-10%) to 24Vdc (20%) |
| Maximum input power | 12,000 |
| Operating Temperature Range | - Integrator Circuit: -5℃ to 65℃- Coils and cables: -20℃ to 80℃ |
| bandwidth (-3dB) | - - ≥2000A: 0.2Hz to 1MHz (300mm), 600kHz (700mm) |
| 50Hz phase shift | - - ≥2000A: 0.4±0.1° |
| Typicalaccuracy | ±1.0% of reading (5%~150% FS, 25℃) |
| Output Load | >10.0 kΩ |
| Coil length | 300mm, 500mm, or 700mm, supports custom lengths |
| Cable length (from coil to electronic unit) | 1m or 2.5m, supports custom length |