PEM
Categories
Probemart.com | Probes, current sensors & calibration sources for pulsed-power testing
Bookmark
PEM
Categories

PEM Rogowski Coil LFR Datasheet.pdf
PEM Rogowski Coil LFR Datasheet.pdf
PEM Rogowski Coil LFR Manual.pdf
PEM Rogowski Coil LFR03 -Noise-Measurements.pdf
PEM Rogowski Coil LFR Technical Note -Technical-Notes-Probemart.pdf
PEM CWT Application Article High Performance Rogowski Current Transducers-W.F.Ray C.R.Hewson Probemart.pdf
PEM Rogowski Coil - A Next-Generation Current Probe for High-Speed, High-Power Measurements -Chrise Hewson.pdf
PEM AC current probeUtilizesa Rogowski coil and matched analog integrator to provide accurate non-contact AC current measurement over a very wide frequency range.
Compared with current transformers (CTs) or Hall-effect current sensors, these flexible clip-on current probes have very low insertion impedance, are easy to insert into narrow spaces, and are not damaged by overcurrent surges.
They can be used to measure AC, pulsed, or transient current waveforms. Because PEM current probes have no magnetic core, they can be used to measure AC current on conductors carrying high DC current or in high DC magnetic fields.
Dual-range, clip-on, battery-powered Rogowski probe for general-purpose AC power measurement. The LFR has a 10:1 switch-selectable current ratio, providing a wide dynamic range in a single probe.
——————————————————————————————————————
Peak current rating from 60A to 60kA
Rugged, flexible, clip-on coil
The Rogowski coil includes an integrator to provide an analog signal precisely proportional in amplitude and phase to the primary current.
High-voltage isolation and common-mode rejection
Measures AC current even in the presence of high DC current
Unaffected by high DC magnetic fields
Bandwidth from 0.1Hz to 1MHz
No I*t limitation, as with CTs
Battery (4xAA) and external DC power supply
CE mark
Special low-temperature version
Special long-coil version
——————————————————————————————————————
Current waveform monitoring in semiconductor switches
Development, testing, and servicing of power-electronics equipment.
Pulsed-power capacitor discharge and magnetic accelerator current measurement
Welding, motor drives, generators, current
Ground currents in rotating machine shafts
Induction heating and plasma current measurement
AC current measurement in the presence of large DC currents
Fault monitoring, circuit-breaker interruption, and lightning-strike currents
Ripple current monitoring in batteries and capacitors
——— Related Applications ———
——— Related Products ———
PMK FireFly®FF-1500A optically isolated probe 1.3 GHz/1.5 GHz high CMRR (180 dB) high-voltage 2500 V double-pulse VGS gate /VDS drain voltage
IWATSU multi-channel high-voltage high-frequency optically isolated measurement probe Isolation SE-6000 remote UHV safety test system
CIC high-voltage differential probe DP20-20K-LVC high-precision 0.1% high-frequency isolated high CMRR 20 kV
| Parameter | Value |
|---|---|
| Rated Current | 6000 A |
| Low Frequency Cut-off | 0.07 Hz |
| Typical Accuracy | 0.5% |
| Phase Error at 50Hz |