Tektronix high-voltage differential prob Tektronix Catalog
Tektronix high-voltage differential probe TDP1000 high-frequency isolated 42 V/30 Vrms high-bandwidth 1 GHz
  • Tektronix high-voltage differential probe TDP1000 high-frequency isolated 42 V/30 Vrms high-bandwidth 1 GHz

Tektronix high-voltage differential probe TDP1000 high-frequency isolated 42 V/30 Vrms high-bandwidth 1 GHz

Brand: Tektronix

Origin: USA

TDP1000, TDP0500 and P6251 high-voltage differential probe provides power supply (SMPS), CAN/LIN and high-speed system design and performance
Overview

The TDP1000, TDP0500, and P6251 high-voltage differential probes provide the excellent high-speed electrical and mechanical performance required by today's switch-mode power supply (SMPS), CAN/LIN bus, and high-speed digital system designs.

Key performance specifications
  • 1 GHz and 500 MHz probe bandwidth

  • 1 MΩ differential input resistance

  • ±42 V (DC + pk AC) differential input voltage

  • >18 dB CMRR (250 MHz, 50X attenuation)


Key features
  • Excellent electrical performance

    • Selectable bandwidth-limit filter

    • DC rejection

  • Versatile DUT connection

    • Small, compact probe for probing small-geometry circuit elements

    • Straight-pin, square-pin, solder, and variable-pitch standard accessories

    • Rugged design for reliability

  • Ease of use

    • Direct connection to TekProbe™ interface oscilloscopes, or connection to TekConnect® oscilloscopes using the TCA-BNC adapter

    • Direct connection to oscilloscopes using the TekVPI™ probe interface

    • Easy access to the probe menu displayed on the oscilloscope for probe setup control and operating status information

    • Remote GPIB/USB probe control through the oscilloscope

    • AutoZero – zeroes the output offset

    • Provides automatic unit scaling and readout on the oscilloscope display

    • TDP1000, TDP0500

    • P6251

Applications
  • High-speed switching power supply design

  • CAN/LIN bus design

  • Digital design and characterization

  • Manufacturing engineering testing

  • Research and development


High-voltage differential probe

The TDP1000, TDP0500, and P6251 high-voltage differential probes are specifically designed for use with and direct connection to Tektronix oscilloscopes equipped with the TekVPI™ probe interface or TekProbe BNC interface. These probes achieve high-speed signal acquisition and measurement fidelity by addressing three traditional measurement challenges:

 

  • Excellent electrical performance

  • Versatile device-under-test connection

  • Ease of use

 


Specifications
型号 衰减 带宽 输入阻抗 最大电压
P5200A 50X / 500X 50 MHz

10 MΩ || 2 pF

500X:  ± 1300 V
50X: ± 130 V

P5205A 50X / 500X 100 MHz

10 MΩ || 2 pF

500X:  ± 1300 V
50X: ± 130 V

P5202A
20X / 200X 100 MHz

5 MΩ || 2 pF

200X:± 640 V
20X:± 64 V

THDP0200 50X / 500X 200 MHz

10 MΩ || 2 pF

500X:± 1500 V
50X:

TMDP0200 25X / 250X 200 MHz

5 MΩ || 2 pF

250X:± 750 V
25X:± 75 V

THDP0100 100X / 1000X 100 MHz

40 MΩ || 2.5 pF

1000X:± 6000 V
100X:± 600 V

P5210A 100X / 1000X 50 MHz

40 MΩ || 2.5 pF

1000X:± 5600 V
100X:± 560 V

TDP0500 5X / 50X 500 MHz

1 MΩ || ≤ 1 pF

±42 v (DC + pk AC)

 30 Vrms

TDP1000 5X / 50X 1 GHz

1 MΩ || ≤ 1 pF

P6251 5X / 50X 1 GHz

1 MΩ || ≤ 1 pF


Expand Tektronix high-voltage differential prob

* Specifications are subject to change without notice.