T&M Research
Categories
Probemart.com | Probes, current sensors & calibration sources for pulsed-power testing
Bookmark
T&M Research
Categories

The Hi-Wattage model is the standard model. The wattage is based on high-current connections and open installation. The enclosure temperature should not exceed 140°F (60°C).
In addition, models with heat sinks require an airflow of 150 cubic feet per minute (4.2 cubic meters) above the enclosure.
The ambient temperature should not exceed 86°F (30°C).
When operating above this temperature, the wattage rating should be reduced accordingly.
——— Related Applications ———
——— Related Products ———
PMK FireFly®FF-1500A optically isolated probe 1.3 GHz/1.5 GHz high CMRR (180 dB) high-voltage 2500 V double-pulse VGS gate /VDS drain voltage
IWATSU multi-channel high-voltage high-frequency optically isolated measurement probe Isolation SE-6000 remote UHV safety test system
CIC high-voltage differential probe DP20-20K-LVC high-precision 0.1% high-frequency isolated high CMRR 20 kV
| Series | Resistance (Ohm) | bandpass MHz | rise time nsec | Emax Joule |
| 75 Watt High Power Unit - 7 7/8 inches | ||||
| F-250-1 | 0.02 | 800 | 0.45 | 250 |
| F-500-2 | 0.01 | 200 | 2 | 500 |
| F-1000-4 | 0.005 | 48 | 8 | 1000 |
| F-2000-8 | 0.0025 | 12 | 30 | 2000 |
| F-2500-10 | 0.002 | 8 | 45 | 2500 |
| F-4000-16 | 0.00125 | 3.2 | 113 | 4000 |
| F-5000-20 | 0.001 | 2.2 | 164 | 5000 |
| F-8000-32 | 0.000625 | 1 | 250 | 8000 |
| F-10000-40 | 0.0005 | 0.58 | 872 | 10000 |
| 90 Watt High Power Unit - 8 7/8 inches | ||||
| F-300-1 | 0.025 | 800 | 0.45 | 300 |
| F-3000-10 | 0.0025 | 8 | 45 | 3000 |
| F-16000-40 | 0.0008 | 0.58 | 872 | 16000 |
| Model | High power | Fin Model | ||
| 7 7/8" 250 watts | 75 watts | 250 watts | ||
| 8 7/8" 300 watts | 90 watts | 300 watts | ||