Tronovo
Categories
Probemart.com | Probes, current sensors & calibration sources for pulsed-power testing
Bookmark
Tronovo
Categories

The DP1010 differential probe is suitable for all mainstream oscilloscopes on the market,
converting floating signals into low-voltage signals referenced to ground, allowing any ground-referenced oscilloscope to display them safely and easily.
The probe operates at frequencies up to 100MHz and can handle voltage signals up to 1300V,
with high common-mode rejection capabilities, making it an excellent choice for non-ground-referenced, floating, or isolated measurements.
Oscilloscope differential probes are very suitable for power testing, switching power supplies, inverters, motor drive control, switching power supply R&D, and maintenance evaluation use.
Product Features:
• Safe floating ground measurements
• Will not damage the oscilloscope or the device under test
• Strong anti-interference capability
• Precise timing positioning
• High measurement accuracy
• High common-mode rejection ratio
——— Related Applications ———
——— Related Products ———
PMK FireFly®FF-1500A optically isolated probe 1.3 GHz/1.5 GHz high CMRR (180 dB) high-voltage 2500 V double-pulse VGS gate /VDS drain voltage
IWATSU multi-channel high-voltage high-frequency optically isolated measurement probe Isolation SE-6000 remote UHV safety test system
CIC high-voltage differential probe DP20-20K-LVC high-precision 0.1% high-frequency isolated high CMRR 20 kV
| Model | DP1010 |
| Bandwidth (-3dB) | , for switching transients of |
| rise time | ≤3.5ns |
| Accuracy | ±2% |
| Range selection (attenuation ratio) | 50X/500X |
| Maximum differential measurement voltage |
50X: ±130V DC Peak AC 500X: ±1300V DC Peak AC |
| common-mode voltage | ±1300V DC Peak AC |
| Maximum input to ground voltage |
600VCAT III 1000VCATⅡ Vrms |
| Input impedance |
Single-ended to ground: 4 MΩ Between the two input terminals: 8 MΩ |
| Input capacitance |
Single-ended to ground: Between the two input terminals: |
| CMRR |
DC: >80dB 100KHz: >60dB 1MHz: >50dB |
| noise level |
50X: ≤75mVrms 500V: ≤500mVrms |
| Overload indication voltage threshold |
50X: ≥140V 500X: ≥1400V |
| Power supplies | DC 9V/1A adapter |