Tronovo
Categories
Probemart.com | Probes, current sensors & calibration sources for pulsed-power testing
Bookmark
Tronovo
Categories

The HDP0100B high-voltage differential probe is suitable for all mainstream oscilloscopes on the market,
converting floating signals into low-voltage signals at reference ground level, allowing any oscilloscope with a reference ground to display signals safely and easily.
The probe operates at frequencies up to 100MHz and can be used for voltage signals up to 3000V,
with high common-mode rejection capability, making it an excellent choice for non-ground-referenced, floating, or isolated measurements.
Using an oscilloscope differential probe is very suitable for power testing, switching power supplies, inverters, motor drive controls, research and development of switching power supplies, and maintenance evaluations.
Product Features
• Safe floating ground measurements
• Does not damage the oscilloscope or the tested device
• Strong anti-interference capability
• Audio-visual alarm function
• 5MHz bandwidth limiting option
• Excellent common-mode noise suppression capability
——— Related Applications ———
——— Related Products ———
PMK FireFly®FF-1500A optically isolated probe 1.3 GHz/1.5 GHz high CMRR (180 dB) high-voltage 2500 V double-pulse VGS gate /VDS drain voltage
IWATSU multi-channel high-voltage high-frequency optically isolated measurement probe Isolation SE-6000 remote UHV safety test system
CIC high-voltage differential probe DP20-20K-LVC high-precision 0.1% high-frequency isolated high CMRR 20 kV
| Model | HDP0100B |
| Bandwidth (-3dB) | , for switching transients of |
| rise time | ≤3.5ns |
| Accuracy | ±2% |
| Range selection (attenuation ratio) | 100X/1000X |
| Maximum differential measurement voltage |
100X: ±300V DC Peak AC 1000X: ±3000V DC Peak AC |
| common-mode voltage | ±3000V DC Peak AC |
| Maximum input to ground voltage |
600VCAT III 1000VCATⅡ Vrms |
| Input impedance |
Single-ended to ground: 5MΩ ±1% Between the two input terminals: 10MΩ ±1% |
| Input capacitance |
Single-ended to ground: Between the two input terminals: |
| CMRR |
DC: >80dB 100KHz: >60dB 1MHz: >50dB 3.2MHz: >30dB 50MHz: >26dB |
| noise level |
100X: 1000V: |
| Overload indication voltage threshold |
100X: ≥300V 1000X: ≥3000V |
| bandwidth Limit (5MHz) long | ≥-3dB@5MHz |
| Overload Indicator Light | There is a (red light) |
| Overload audible alarm | Available (can be turned off) |
| Auto-save function | there are |
| Adjustable offset (bias) function | Yes (adjustable in test mode) |
| Terminal load requirement | ≥100 kΩ |
| Power supplies | USB 5V/1A adapter |
| Safety compliance standards | EN61010-1:2010 |
| EMC compliance standards | EN61326-1:2013 EN61000-3-3:2013 |