Tronovo high-performance high-voltage differential probe HDP0100B (100M/3000 V)
  • Tronovo high-performance high-voltage differential probe HDP0100B (100M/3000 V)

Tronovo high-performance high-voltage differential probe HDP0100B (100M/3000 V)

Brand: Tronovo

Origin: China

Probe up to 100 MHz, for 3000 V voltage, with high-common-mode rejection, non-, isolated measurement choosing
Overview


The HDP0100B high-voltage differential probe is suitable for all mainstream oscilloscopes on the market,

converting floating signals into low-voltage signals at reference ground level, allowing any oscilloscope with a reference ground to display signals safely and easily.

The probe operates at frequencies up to 100MHz and can be used for voltage signals up to 3000V,

with high common-mode rejection capability, making it an excellent choice for non-ground-referenced, floating, or isolated measurements.

Using an oscilloscope differential probe is very suitable for power testing, switching power supplies, inverters, motor drive controls, research and development of switching power supplies, and maintenance evaluations.




Product Features


• Safe floating ground measurements

• Does not damage the oscilloscope or the tested device

• Strong anti-interference capability

• Audio-visual alarm function

• 5MHz bandwidth limiting option

• Excellent common-mode noise suppression capability


Specifications
Model HDP0100B
Bandwidth (-3dB) , for switching transients of
rise time ≤3.5ns
Accuracy ±2%
Range selection (attenuation ratio) 100X/1000X
Maximum differential measurement voltage

100X: ±300V DC Peak AC

1000X: ±3000V DC Peak AC

common-mode voltage ±3000V DC Peak AC
Maximum input to ground voltage

600VCAT III

1000VCATⅡ Vrms

Input impedance

Single-ended to ground: 5MΩ ±1%

Between the two input terminals: 10MΩ ±1%

Input capacitance

Single-ended to ground:

Between the two input terminals:

CMRR

DC: >80dB

100KHz: >60dB

1MHz: >50dB

3.2MHz: >30dB

50MHz: >26dB

noise level

100X:

1000V:

Overload indication voltage threshold

100X: ≥300V

1000X: ≥3000V

bandwidth Limit (5MHz) long ≥-3dB@5MHz
Overload Indicator Light There is a (red light)
Overload audible alarm Available (can be turned off)
Auto-save function there are
Adjustable offset (bias) function Yes (adjustable in test mode)
Terminal load requirement ≥100 kΩ
Power supplies USB 5V/1A adapter
Safety compliance standards EN61010-1:2010
EMC compliance standards

EN61326-1:2013     EN61000-3-3:2013