The TR9328A can measure DC voltage up to 28 kV and AC voltage up to 20 kV; it has 500 MΩ input impedance and low loading effect, and its 200 MHz high bandwidth enables capturing fast, high-voltage signals.
The high-voltage probe can be connected directly to an oscilloscope for measurement and is suitable for high-voltage ground-referenced voltage measurement. An optional adapter also enables voltage measurement with a digital multimeter.
The TR9328A uses an environmentally harmless silicone resin insulating medium, which improves insulation performance, ensures that internal components do not oxidize during high-voltage measurement, and extends service life.
Product Features:
• Maximum measurement voltage: 28 kV DC+ACpeak
• Bandwidth up to 75 MHz
• Input impedance 500 MΩ
• Fixed attenuation ratio 1000:1, Read Out
• Can be connected to a multimeter for use with an impedance matching adapter
——— Related Applications ———
——— Related Products ———
PMK FireFly®FF-1500A optically isolated probe 1.3 GHz/1.5 GHz high CMRR (180 dB) high-voltage 2500 V double-pulse VGS gate /VDS drain voltage
IWATSU multi-channel high-voltage high-frequency optically isolated measurement probe Isolation SE-6000 remote UHV safety test system
CIC high-voltage differential probe DP20-20K-LVC high-precision 0.1% high-frequency isolated high CMRR 20 kV
| Model | TR9328A |
| attenuation ratio | 1000:1 |
| Read aloud function) | - |
| Input impedance | 500 MΩ |
| Input capacitance | 1.7PF |
| Maximum Input: DC AC peak | 28KV CAT II |
| Maximum Input: AC RMS | 20KV CAT II |
| Pulse Voltage | |
| Maximum load current | 56uA |
| Bandwidth | DC~75MHz |
| rise time | 5.3 nS |
| Noise ratio | >60dB at 1KHz; >50dB at 1MHz |
| DC signal error value | ≤3% full range scale, ≤3% (0-35KV) |
| AC signal error value | ≤3% at 1KHz |
| Temperature coefficient | ≤200 PPM/℃ |
| Matching capacitor adjustment range | 10PF~35PF |
| Safety Standard Inspection | Complies with EN61010-031 CAT II standard |
| Test line length | 2M ± 0.2M |
| Operating Temperature and Humidity | 0~40℃, 80% or less |
| Save temperature and humidity | -10~45℃, 80% or less |
| Color: Grip/Body | Black/Light Gray |
| Size | 80mm x 80mm x 320mm |
| Weight | 460g |