UT-PA2000 and UT-PA1000 It is an active unit designed for high-frequency measurements The terminal probe integrates many features required by today's general high-speed probe, especially In digital system design and signal integrity testing, its 1MΩinput impedance and Extremely low input capacitance (≤1.3 pF) Provided the device under test with an ultra-low load. UT-PA2000 and UT-PA1000 each has 2GHz、1GHz test bandwidth, and below 175hp、350ps of rise time, ±4V dynamics Range, while also taking into account the small signal measurement capability. At the same time, it also provides a variety of options related to the device under test Connecting accessory for flexible connection, used to connect small DUT.probe interface Also specially designed, it can directly connect with the high-end oscilloscope in UNI-T such as MSO7000X,MSO8000HD,UPO7000L Waiting for the connection test, No external power supply is required. Active single-ended probe is widely used in high-speed digital circuits, In many high-speed fields such as bus analysis and signal integrity analysis,UTPA2000 and UT-PA1000 Can accurately and quickly obtain in the circuit Signal information helps improve engineers' work efficiency and accuracy.
Excellentelectrical performance
Height bandwidth-Accurately measure high-speed serial signals
UT-PA2000 Bandwidth:2 GHz
UT-PA1000 Bandwidth:1GHz
Extremely high signal fidelity
UT-PA2000 rise time:175ps
UT-PA1000 rise time:350ps
Ultra-low load (1MΩinput impedance, ≤1.3 pF Input capacitor)
Dynamic range: ±4V
Offset range: ±4V
Transmission delay: ≤8 ns
0.5W Ultra low power dissipation
Excellencemechanical design
Compact probe head for testing small circuit components
Various flexible connections DUT attachment
Unique probe headlight design
Easy to useFunction probe
probeFront light on/Power Off Button
Control oscilloscope operation/Stop
Clear oscilloscope current displayed waveform and measurement values
Control oscilloscope to force trigger
Automatic attenuation factor sensing
Automatic impedance Matching
Identify model probe and serial number
CompatibleOscilloscope
UNI-Toscilloscope interface, no external power supply power supply needed
Adaptation MSO7000X、MSO8000HD、UPO7000L、 MSO5000HD、MSO3000X、MSO3000HD Series
——— Related Applications ———
——— Related Products ———
PMK FireFly®FF-1500A optically isolated probe 1.3 GHz/1.5 GHz high CMRR (180 dB) high-voltage 2500 V double-pulse VGS gate /VDS drain voltage
IWATSU multi-channel high-voltage high-frequency optically isolated measurement probe Isolation SE-6000 remote UHV safety test system
CIC high-voltage differential probe DP20-20K-LVC high-precision 0.1% high-frequency isolated high CMRR 20 kV
Unilead UT-PA2000 / UT-PA1000 Performance Specs
| performance indicators | UT-PA2000 | UT-PA1000 |
|---|---|---|
| bandwidth (-3dB) | 2GHz | 1GHz |
| rise time | ≤175ps | ≤350ps |
| DC attenuation ratio | 10:1±5%.10:1±5% | |
| Enter dynamic range | ±4V (DC or peak AC) | ±4V (DC or peak AC) |
| maximum input voltage | ±12V (non-operating voltage).±12V (non-operating voltage) | |
| Enter the bias range | ±4V | ±4V |
| DC bias error (output 0) | ±2mV±2mV | |
| input capacitor | ≤1.3pF | ≤1.3pF |
| input resistor | 1MΩ ±1%.1MΩ ±1% | |
| transfer delay | ≤8ns≤8ns | |
| flatness (25°C | ).≤1dB(100kHz–500MHz)≤1.5dB(500MHz–1GHz) | ≤1dB(100kHz–500MHz) |
| probe noise (equivalent to input) | ||
| output impedance | 50Ω | 50Ω |
| Static Protection ESD | 8kV HBM | 8kV HBM |
| 0.5W | 0.5W |
| probe specification | parameters |
|---|---|
| weight | |
| cable length | 1.2m|
| probe size | Front: 110mm×18.3mm×20mm. Back: 106.6mm×24mm×27mm|
| compatible oscilloscopes | MSO8000HD, MSO7000X, UPO7000L, MSO5000HD, MSO3000HD MSO3000X
| environment characteristics | Parameters |
|---|---|
| Operating Temperature | 0℃ ~ 40℃ |
| Non-Operating Temperature | -40℃ ~ 70℃ |
| Operating Humidity | 95%RH@40℃ |
| Non-Operating Humidity | 95%RH@65℃ |