High-frequency bandwidth 900MHz
Input voltage range 10Vp-p (DC and AC peak should be within ±10V)
Non-destructive input voltage range ±40V (DC and AC peak)
700939 FET is an active probe
——— Related Applications ———
——— Related Products ———
PMK FireFly®FF-1500A optically isolated probe 1.3 GHz/1.5 GHz high CMRR (180 dB) high-voltage 2500 V double-pulse VGS gate /VDS drain voltage
IWATSU multi-channel high-voltage high-frequency optically isolated measurement probe Isolation SE-6000 remote UHV safety test system
CIC high-voltage differential probe DP20-20K-LVC high-precision 0.1% high-frequency isolated high CMRR 20 kV
| Item | Specifications |
| Frequency bandwidth | DC-900MHz applicable to probe 1 |
| Attenuation rate | 10:1 ±2%, when connected to a 50 ohm ±1% resistor 1 |
| Output offset voltage | ±2mV (±20mV when converted to the input terminal) 1 |
| Input Voltage Range | 10Vp-p (DC ACpeak value should be within ±10V) 1,2 |
| Lossless input voltage range | ±40V (DC ACpeak value) 3 |
| Input resistance | About 2.5 Mohm |
| Input capacity | About 1.8 pF |
| Total cable length | 1.5m (probe cable) 1m (power supply cable) |
| Weight | About 180g |
| Operating Temperature | 5~40 ℃ |
| Environmental working humidity | 20~80% RH (non-condensing) |
| Ambient storage temperature | -20~60 ℃ |
| Environmental storage humidity | 20~80% RH (non-condensing) |
| power supply Voltage | ±12V ±1V (Available range: 11~13V or -11~-13V) |
| power supplyElectric current | The current of terminal power supply is less than 125mA 2 |
| EMC | Radiation complies with standard: EN61326 Class A Anti-interference compliance standard: EN61326 Sensitivity under anti-interference conditions noise Increase±200mV4 |
1Reference working conditions: ambient temperature 23±5°C; ambient humidity 55±10%; after 30 minutes of power-on.
2: When the power supply voltage is ±12V.
3The relationship between frequency bandwidth and input voltage reduction is shown in the figure on the right.
4: Test conditions:
Set the frequency bandwidth to 20 MHz, and the input coupling of oscilloscope to 50 ohms.
Terminate the probe with a 50 ohm resistor. Connect a ferrite core (TDK: ZCAT2035-0930A, YOKOGAWA part number: A1190MN) to all ends of the cable.