Probemart.com | Probes, current sensors & calibration sources for pulsed-power testing

Bookmark Bookmark
Home > Products > Instruments
CIC high-voltage differential probe DP30 CIC Research Catalog
CIC high-voltage differential probe DP30-10K/DP30-10-LVC 0.1% high-precision isolated
  • CIC high-voltage differential probe DP30-10K/DP30-10-LVC 0.1% high-precision isolated

CIC high-voltage differential probe DP30-10K/DP30-10-LVC 0.1% high-precision isolated

Brand: CIC Research

Origin: USA

DP30-10K:1% accuracy, 10000X,20 kVRMS, 30 kV PEAK DP30-10-LVC: 0.1% high-precision
Overview

The American CIC high-voltage differential probe is the world's top-tier high-voltage differential probe, featuring ultra-high precision and high common-mode repression ratio. Applied in fields such as atomic energy, nuclear physics, the Institute of High Energy Physics, and aerospace, the CIC Research DP series high-pressure differential probes adopt the latest proprietary technology, completely breaking through the performance bottlenecks of traditional high-voltage differential probes.    

CIC Research DP series high-voltage differential probes use the latest proprietary technology, completely overcoming the performance bottlenecks of traditional high-voltage differential probes. Especially for measurements of high-voltage, high-common-mode, and high-speed signals, our high-voltage differential probes outperform traditional high-pressure probes by 10 times. At the same time, this high-voltage differential probe provides high-precision measurements while ensuring an extremely low bias voltage.

CIC Research DP high-voltage differential probe uses a special power supply module, giving the probe higher stability and lower noise. Its LVC high-precision series high-voltage probes use

internal components

Extremely low temperature and voltage coefficients, providing extremely high testing accuracy. All active high-voltage differential probes have an output impedance of 50Ω, suitable for all oscilloscopes and voltmeters.



Performance features:

extremely low equivalent input capacitance

  • 75MHz — 120MHz bandwidth (full scale)

  • up to 20KV RMS, 30KV peak voltage

  • accuracy up to 0.1%

  • unmatched common-mode rejection ratio and conversion speed

  • Biased numbers are adjustable

_____________________________________________________________________

Application Fields

The CIC Research DP active high-voltage differential probe is fully capable of handling tests in general power/energy monitoring systems. Its extremely low input capacitance allows testing of higher voltage frequencies. The CIC Research DP high-voltage differential probe has an extremely high frequency response, capable of measuring high-voltage signals exceeding 150MHz, and is widely used in megawatt-class traction inverters, power supply design, power generators, UPS, and more.

Due to the exceptionally high conversion speed of this high-voltage differential probe, it is particularly suitable for research and testing of fuel-powered vehicles, electric vehicles, and hybrid vehicles, as well as testing in electromagnetic systems, high-energy research institutes, nuclear physics research, and special rugged high-voltage broadband signals.


Specifications



Standard model (1%accuracy): high-voltage differential probe
Series DP02-XX DP03-XX DP04-XX DP20-XX DP30-XX
Model suffix 100 1k 2k 10k 100-50 1k-50 2k-50 100 1k 2k 10k 10k 20k 2k 10k
RMS 175V 1.75 kV 3.5 kV 8 kV 600V 6 kV 8 kV 175V 1.75 kV 3.5 kV 8 kV 17.5 kV 20 kV 12kV 20 kV
peak voltage 200V 2 kV 4 kV 12k 700V 7k 12k 200V 2 kV 4 kV 12k 20 kV 30 kV 14 kV 30 kV
Voltage division ratio 1:100 1:1k 1:2k 1:10,000 1:100 1:1k 1:2k 1:100 1:1k 1:2k 1:10,000 1:10,000 1:20,000 1:2k 1:10,000
Accuracy 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1%
Bandwidth , for switching transients of 75 MHz Bandwidth Bandwidth 75 MHz
Note: The specific product model = replace XX in the series with the model suffix, such as DP02-100, DP03-1K-50

High accuracy model (0.1% accuracy): High accuracyhigh-voltage differential probe
Series DP02-XX-LVC DP03-XX-LVC-50 DP04-XX-LVC DP20-XX-LVC DP30-XX-LVC
Model suffix 100 1k 2k 100k 100 1k 2k 100 1k 2k 10k 10k 20k 2k 10k
RMS 175V 1.75 kV 3.5 kV 6.3 kV 175V 6 kV 8 kV 175V 1.75 kV 3.5 kV 6.3 kV 17.5 kV 20 kV 12kV 20 kV
peak voltage 200V 2 kV 4 kV 12k 200V 7k 12k 200V 2 kV 4 kV 12kV 20 kV 30 kV 14 kV 30 kV
Voltage division ratio 1:100 1:1k 1:2k 1:10,000 1:100 1:1k 1:2k 1:100 1:1k 1:2k 1:10,000 1:10,000 1:20,000 1:2k 1:10,000
Accuracy 0.1% 0.1% 0.1% 0.1% 0.1% 0.1% 0.1% 0.1% 0.1% 0.1% 0.1% 0.1% 0.1% 0.1% 0.1%
Bandwidth , for switching transients of 75 MHz Bandwidth Bandwidth 75 MHz
Explanation: The specific product model = replace XX in the series of model suffixes, such as DP02-100-LVC, DP03-1K-LVC-50


For more model and range options, please contact sales personnel*

Expand CIC high-voltage differential probe DP30

* Specifications are subject to change without notice.