The CP9000 (S/L) A series flexible current probes are probes designed for testing AC current signals only, featuring high bandwidth and high accuracy (typical value of 2%).
They can achieve a wide current measurement range, with frequencies from a few Hz to tens of MHz, and current ranges from mA level to several kA, greatly solving the difficulties in current testing.
Their main features include:
The coil is lightweight, flexible, and can be freely inserted and removed, allowing access to many places that rigid probes cannot reach, making it easy to connect to the object under test;
The insertion loss is almost zero, only a few pH, causing near-zero interference to the object under test;
Standard BNC output interface, conveniently connecting to oscilloscopes, data acquisition devices, digital voltmeters, etc., to observe current waveforms;
Powered by 4 AA batteries or external USB DC 5V power, offering more flexible and convenient use; audio-visual overcurrent alarm function, providing a more user-friendly design;
The probe loop and connection cable length can be customized according to customer requirements, meeting testing needs in special situations.
The CP9000A series probe loops have typical outer diameters of 3.5mm and 4.5mm, with withstand voltages up to 2kVpk and 5kVpk respectively. The sensing loop can navigate freely in confined spaces, suitable for high-current measurement scenarios.
——— Related Applications ———
——— Related Products ———
PMK FireFly®FF-1500A optically isolated probe 1.3 GHz/1.5 GHz high CMRR (180 dB) high-voltage 2500 V double-pulse VGS gate /VDS drain voltage
IWATSU multi-channel high-voltage high-frequency optically isolated measurement probe Isolation SE-6000 remote UHV safety test system
CIC high-voltage differential probe DP20-20K-LVC high-precision 0.1% high-frequency isolated high CMRR 20 kV
(Measurement conditions: 23°C; 60% RH; the wire under test passes through the center of the probe induction loop.)
CP9000ASeries
Model |
Sensitivity(mV/A) |
peak Value |
Maximum noise(mV Vpp) |
Attenuation characteristics(%/ms) |
Low frequencybandwidth-3dB(Hz) |
High frequency bandwidth-3dB(MHz) |
Typical Accuracy |
insulation Voltage value |
|
Current(kA) |
dI/dt (kA/µs) |
||||||||
CP9012A |
50 |
0.12 |
1 |
12 |
9.5 |
10 |
15 |
2% |
2 kV |
CP9030A |
20 |
0.3 |
2.5 |
12 |
4.5 |
4.8 |
15 |
||
CP9060A |
10 |
0.6 |
5.0 |
10 |
2.0 |
2.3 |
15 |
||
CP9120A |
5 |
1.2 |
10 |
10 |
1.3 |
1.5 |
15 |
||
CP9300A |
2 |
3.0 |
25 |
8 |
1.3 |
1.5 |
15 |
||
CP9600A |
1 |
6.0 |
40 |
7 |
1.3 |
1.5 |
15 |
||
CP9121A |
0.5 |
12 |
40 |
5 |
0.8 |
1 |
15 |
||
CP9301A |
0.2 |
30 |
40 |
5 |
0.8 |
1 |
15 |
||
CP9601A |
0.1 |
60 |
40 |
5 |
0.8 |
1 |
15 |
||
CP9122A |
0.05 |
120 |
40 |
5 |
0.8 |
1 |
15 |
||