The CP9000 (S/L) A series flexible current probe is a probe that only tests AC current signals, featuring high bandwidth and high accuracy (typical value 2%).
It can achieve a wide range of current measurements, with frequencies ranging from a few Hz to tens of MHz, and current ranges from the mA level to several kA, greatly solving the difficulties in current testing.
Its main features include:
The coil is lightweight, soft, and freely detachable, allowing detection in areas that many rigid probes cannot reach and easily connecting with the object under test;
The insertion loss is nearly zero, only a few picohenries, causing almost no interference to the object under test;
Standard BNC output interface, convenient for connection to oscilloscopes, data acquisition devices, digital voltmeters, etc., for observing current waveforms;
Powered by 4 AA batteries or an external USB DC5V power supply, offering more flexible and convenient use;
Audio-visual overcurrent alarm function, making it more user-friendly;
Probe loop and cable length can be customized according to customer requirements to meet testing needs in special situations.
The CP9000SA series probe has a small and flexible sensing loop, with typical wire diameters of 2.5mm, 2.5mm*1.2mm, and 1.6mm, and a withstand voltage of up to 1kVpk. It is especially suitable for current measurement of pins of MOSFETs and IGBT devices (TO-220, TO-47 packaging), capacitor ripple current measurement, and other small package device current measurements.
——— Related Applications ———
——— Related Products ———
PMK FireFly®FF-1500A optically isolated probe 1.3 GHz/1.5 GHz high CMRR (180 dB) high-voltage 2500 V double-pulse VGS gate /VDS drain voltage
IWATSU multi-channel high-voltage high-frequency optically isolated measurement probe Isolation SE-6000 remote UHV safety test system
CIC high-voltage differential probe DP20-20K-LVC high-precision 0.1% high-frequency isolated high CMRR 20 kV
(Measurement conditions:23°C; 60% RH; the tested wire passes through the center of the probe induction loop.)
1 CP9000SA Series
Model |
Sensitivity(mV/A) |
peak Value |
Maximum noise (mV Vpp) |
Attenuation characteristics(%/ms) |
Low frequencybandwidth-3dB(Hz) |
High frequency bandwidth-3dB(MHz) |
Typical Accuracy |
insulation Voltage Value |
|
Current(kA) |
dI/dt (kA/µs) |
||||||||
CP9003SA |
200 |
0.03 |
2 |
20 |
80 |
116 |
30 |
2% |
1 kV |
CP9006SA |
100 |
0.06 |
4 |
20 |
65 |
67 |
30 |
||
CP9012SA |
50 |
0.12 |
8 |
15 |
35 |
34 |
30 |
||
CP9030SA |
20 |
0.3 |
20 |
15 |
9 |
9.2 |
30 |
||
CP9060SA |
10 |
0.6 |
40 |
10 |
6 |
6.2 |
30 |
||
CP9120SA |
5 |
1.2 |
70 |
10 |
3 |
3.2 |
30 |
||
CP9300SA |
2 |
3.0 |
70 |
5 |
2 |
2 |
30 |
||
CP9600SA |
1 |
6.0 |
70 |
5 |
2 |
2 |
30 |
||
CP9121SA |
0.5 |
12 |
70 |
5 |
2 |
2 |
30 |
||