The HCP8000 series current probes are high-frequency current probes capable of measuring both DC and AC currents.
Main features of the HCP8000 series:
High bandwidth, can accurately and quickly capture current waveforms;
High precision, with accuracy up to 1% within the current measurement range, meeting the needs of most testing fields;
Two selectable ranges, convenient for measuring small currents;
Automatic degaussing and zeroing function, easy to use;
Audible and visual overcurrent alarm function, reminding of range switching;
Electronic touch-type key design, longer service life;
Standard BNC output interface, compatible with oscilloscopes from any manufacturer.
The HCP8030 is compact and can be easily used on currently crowded circuit boards;
The small clamp can detect current in tight spaces while still clamping wires up to 5mm in diameter;
It can measure 30A continuous current and 50A peak current, and the HCP8030 provides 50MHz bandwidth;
The probe offers two selectable ranges: 30A (10X) and 5A (1X), with the 5A (1X) range being especially suitable for measuring small currents, with a resolution up to 1mA.
——— Related Applications ———
——— Related Products ———
PMK FireFly®FF-1500A optically isolated probe 1.3 GHz/1.5 GHz high CMRR (180 dB) high-voltage 2500 V double-pulse VGS gate /VDS drain voltage
IWATSU multi-channel high-voltage high-frequency optically isolated measurement probe Isolation SE-6000 remote UHV safety test system
CIC high-voltage differential probe DP20-20K-LVC high-precision 0.1% high-frequency isolated high CMRR 20 kV
Product Electrical Specifications
Model Number |
HCP8030C |
||
Bandwidth(-3dB) |
DC-70 MHz (Figure1.b) |
||
rise time |
≤5ns |
||
|
Continuous current Maximum value |
30Arms Figure2.b |
||
Peak current |
50Apk |
||
Range |
5A |
1Xattenuation |
|
30A |
10Xattenuation |
||
Overcurrent Alarm Value |
5A |
≥5APK |
|
30A |
≥50APK |
||
Current transmission ratio |
5A |
1V/A |
|
30A |
0.1 V/A |
||
resolution |
5A |
1 mA |
|
30A |
10mA |
||
|
Accuracy (DC, 45-66Hz)Maximum continuous current) |
5A |
±1%±1 mA |
|
30A |
±1%±10mA |
||
Input impedance |
Reference image3.b |
||
|
extend time |
probe Host |
14 ns |
|
|
BNC (1 meter) |
5ns |
||
Terminal load requirement |
≥100 kΩ |
||
Power supply method |
DC 12V/1A(Standard adapter) |
||
Insulated wire voltage |
300V CAT I |
||
Safety compliance standards |
EN61010-1: 2010 A1:2019 EN 61010-2-032:2019 |
||
EMCCompliance standards |
EN61326-1:2013 EN61000-3-2:2014 EN61000-3-3:2013 |
||