Danisense
Categories
Probemart.com | Probes, current sensors & calibration sources for pulsed-power testing
Bookmark
Danisense
Categories

Danisense Fluxgate Sensor DM1200UB-1V Datasheet.pdf
Danisense Fluxgate Current Probe Product Manual DS_Product_Manual-Probemart.pdf
Danisense Fluxgate Current Probe Selection Guide (Probemart)Products selection guide 2022.8v0-en.pdf
Danisense Fluxgate DSSIU-6 How-to-modify-a-DSSIU-6-from-voltage-to-current.pdf
Danisense Overview RCM-by-Danisense.pdf
Danisense Current Sensor Principle - Probemart.pdf
Brand Danisense, Origin Denmark. Danisense current sensors are based on zero-fluxgate sensor technology.
Ultra-stable, high-precision (ppm-level) fluxgate current sensors are used for non-intrusive, isolated DC and AC current measurements.
A fluxgate sensor uses the nonlinear relationship between the magnetic induction of a high-permeability core and the magnetic field under alternating magnetic field saturation excitation to measure weak magnetic fields. This physical phenomenon acts like a "gate" for the measured environmental magnetic field, and the corresponding magnetic flux is modulated as it passes through this "gate," generating an induced electromotive force. This phenomenon is used to measure the magnetic field generated by current, thereby indirectly achieving current measurement. Fluxgate sensors are based on the nonlinear magnetization characteristics of core materials. Their sensitive elements are cores made of high-permeability, easily saturable materials, with two windings around the core: one is the excitation coil, and the other is the signal coil. Under the magnetization effect of an alternating excitation signal, the permeability characteristics of the core undergo periodic saturation and non-saturation changes, allowing the coil surrounding the core to sense signals responding to the external magnetic field. Danisense is the benchmark for fluxgate sensors in the industry. The domestic high-tech company Hangzhi Technology’s fluxgate products adopt multi-point zero-flux patented technology and are an emerging global brand for high-precision current measurement.
Advantages and Features:
Ø45mm aperture allows for large isolated cables and high-precision leakage current measurements.
1 ppm linearity
10 ppm offset
Current output
Fluxgate, closed-loop compensation technology, and crystal-driven excitation frequency to improve stability
Industrial standard DSUB 9-pin connector
All-aluminum body provides excellent EMI shielding and extended operating temperature range
Typical Applications
Power measurement and power analysis
Stable power supplies
MPS for particle accelerators
Gradient amplifiers for MRI equipment
Precision drives
Battery testing and evaluation systems
Current calibration purposes
——— Related Applications ———
——— Related Products ———
PMK FireFly®FF-1500A optically isolated probe 1.3 GHz/1.5 GHz high CMRR (180 dB) high-voltage 2500 V double-pulse VGS gate /VDS drain voltage
IWATSU multi-channel high-voltage high-frequency optically isolated measurement probe Isolation SE-6000 remote UHV safety test system
CIC high-voltage differential probe DP20-20K-LVC high-precision 0.1% high-frequency isolated high CMRR 20 kV
| Danisensecurrent sensor High-Frequency DT Series 0–200A: | |||||
| Model | Current range | Product Dimensions (mm) | Aperture (mm) | Transformation ratio | Output port |
| Current output type | |||||
|
DT50ID |
50A | 65.5×54.5×35 | 20.7 | 500:1 | DSUB9 |
|
DT100ID |
100A | 65.5×54.5×35 | 20.7 | 1000:1 | DSUB9 |
|
DT200ID |
200A | 65.5×54.5×35 | 20.7 | 1000:1 | DSUB9 |
| Danisensecurrent sensor0~1000A: | |||||
| Model (0-1KA) | Current range | Product Dimensions (mm) | Aperture (mm) | Transformation ratio | Output port |
| Faston connection | |||||
|
DC200IF |
300A | 80×61.5×41.5 | 20 | 1:1000 | Faston |
| DSUB current output type | |||||
|
DS50ID |
150A | 121.4×107.5×44.5 | 27.6 | 1:500 | DSUB9 |
|
DS200ID |
370A | 121.4×107.5×44.5 | 27.6 | 1:500 | DSUB9 |
|
DS300ID |
500A | 121.4×107.5×44.5 | 27.6 | 1:1000 | DSUB9 |
|
DS400ID |
600A | 121.4×107.5×44.5 | 27.6 | 1:2000 | DSUB9 |
|
DS600ID |
1000A | 121.4×107.5×44.5 | 27.6 | 1:1500 | DSUB9 |
|
DQ500ID |
800A | 104×106×47 | 28.1 | 1:1750 | DSUB9 |
|
DQ600ID |
1000A | 104×106×47 | 28.1 | 1:1500 | DSUB9 |
| DQ640ID-B | 640A | 104×106×47 | 28.1 | 40A-640A | DSUB9 |
|
DQ600ID-P1300 |
1300A | 104×106×47 | 28.1 | 1:1500 | DSUB9 |
| BNC voltage output type | |||||
|
DS50UB-1V |
150A | 121.4×107.5×44.5 | 27.6 | 1V:50A | DSUB9/BNC |
|
DS50UB-10V |
55A | 121.4×107.5×44.5 | 27.6 | 10V:50A | DSUB9/BNC |
|
DS200UB-1V |
300A | 121.4×107.5×44.5 | 27.6 | 1V:200A | DSUB9/BNC |
|
DS200UB-10V |
220A | 121.4×107.5×44.5 | 27.6 | 10V:200A | DSUB9/BNC |
|
DS300UB-1V |
500A | 121.4×107.5×44.5 | 27.6 | 1V:300A | DSUB9/BNC |
|
DS300UB-10V |
330A | 121.4×107.5×44.5 | 27.6 | 10V:300A | DSUB9/BNC |
|
DS400UB-1V |
600A | 121.4×107.5×44.5 | 27.6 | 1V:400A | DSUB9/BNC |
|
DS400UB-10V |
440A | 121.4×107.5×44.5 | 27.6 | 10V:400A | DSUB9/BNC |
|
DS600UB-1V |
900A | 121.4×107.5×44.5 | 27.6 | 1V:600A | DSUB9/BNC |
|
DS600UB-10V |
660A | 121.4×107.5×44.5 | 27.6 | 10V:600A | DSUB9/BNC |
|
DS1000UB-10V |
1100A | 121.4×107.5×44.5 | 27.6 | 10V:1000A | DSUB9/BNC |
| BNC voltage output type | |||||
| DS200ID-CD100 | 370A | 121.4×107.5×44.5 | 27.6 | 1:500 | DSUB9 |
| DS200ID-CD1000 | 370A | 121.4×107.5×44.5 | 27.6 | 1:500 | DSUB9 |
| DS600ID-CD100 | 1000A | 121.4×107.5×44.5 | 27.6 | 1:1500 | DSUB9 |
| Danisensecurrent sensor1000–3000A: | |||||
| Model (1-3KA) | Current range | Product Dimensions (mm) | Aperture (mm) | Transformation ratio | Output port |
| DSUB current output | |||||
|
DM1200ID |
1800A | 178.6×174×53 | 45 | 1:500 | DSUB9 |
|
DL2000ID |
3000A | 239.8×230×82 | 68 | 1:500 | DSUB9 |
| BNC voltage output (2ppm/k) | |||||
|
DM1200UB-1V |
1800A | 178.6×174×53 | 45 | 1V:2000A | DSUB9/BNC |
|
DM1200UB-10V |
1320A | 178.6×174×53 | 45 | 10V:2000A | DSUB9/BNC |
|
DL2000UB-1V |
3000A | 239.8×230×82 | 68 | 1V:2000A | DSUB9/BNC |
|
DL2000UB-10V |
3000A | 239.8×230×82 | 68 | 10V:2000A | DSUB9/BNC |
| Calibration winding BNC | |||||
| DL2000ID-CB100 | 3000A | 239.8×230×82 | 68 | 1:500 | DSUB9/BNC |
| Calibration winding DSUB | |||||
| DL2000ID-CD100 | 3000A | 239.8×230×82 | 68 | 1:500 | DSUB9 |
| Danisensecurrent sensorAbove 3000A: | |||||
| Model (0-1KA) | Current range | Product Dimensions (mm) | Aperture (mm) | Transformation ratio | Output port |
| Current output | |||||
|
DR5000IM |
8000A | 420×325×122 | 150 | 1:2500 | 4mm banana head |
|
DR10000IM |
11000A | 420×325×122 | 140 | 1:2500 | 4mm banana head |
| DSUB current output type | |||||
|
DR5000UX-10V_5000A |
550 | 420×325×122 | 150 | 1V:50A | 3-pin XLR Mini |
|
DR5000UX-10V_7500A |
8000A | 420×325×122 | 150 | 1.333V:KA | 3-pin XLR Mini |
| DR5000UX-10V | 11000A | 420×325×122 | 140 | 1V:1KA | 3-pin XLR Mini |