IWATSU
Categories
Probemart.com | Probes, current sensors & calibration sources for pulsed-power testing
Bookmark
IWATSU
Categories

IWATSUIWATSU Rogowski Coil Rogowski Datasheet datasheet.pdf
IWATSU rogowski IWATSU Rogowski Current Probe SS-280A Manual.pdf
IWATSUIWATSU Rogowski Coil Rogowski Datasheet datasheet.pdf
IWATSU Rogowski Coil User Guide.pdf
IWATSU Current Probe Current Probe ?-Probemart.pdf
IWATSU Technical Material Rogowski Coil _ -Probemart.pdf
IWATSU Rogowski Coil Signal Droop Characteristics _ Technical Material _ -Probemart.pdf
IWATSU Application Article Rogowski Coil Overview -Probemart.pdf
IWATSU Application Article Rogowski Current Probe Principle -Probemart.pdf
Wide-Bandgap Device Dynamic Characterization iV1.03_2023_jectronic.pdf
The SS-280 series uses an open flexible coil with a maximum wire diameter of 1.7mm, capable of passing through pin tests, suitable for narrow and extremely small spaces, with a coil length of 84mm,
Compared with traditional current sensors, it is easier to install and use, and can measure and monitor current online.
————————————————————————————————————————————————————
Main Features of SS-280 Series:
The tip diameter of the probe is as small as 1.7mm, capable of directly probing TO-type MOSFETs and IGBTs used in switch-mode power supplies and other power electronic devices.
It has a frequency bandwidth of 30MHz, allowing observation of high-frequency switching waveforms.
Current measurement range is 30A~30000A, supporting various current measurements. Since it does not magnetically saturate, it can safely measure high currents.
The probe operating temperature range is -40℃~125℃.
——— Related Applications ———
——— Related Products ———
PMK FireFly®FF-1500A optically isolated probe 1.3 GHz/1.5 GHz high CMRR (180 dB) high-voltage 2500 V double-pulse VGS gate /VDS drain voltage
IWATSU multi-channel high-voltage high-frequency optically isolated measurement probe Isolation SE-6000 remote UHV safety test system
CIC high-voltage differential probe DP20-20K-LVC high-precision 0.1% high-frequency isolated high CMRR 20 kV
| Parameter | Value |
|---|---|
| Peak Current | 3000 A |
| High Frequency Bandwidth | 30 MHz |
| Low Frequency Cut-off | 2 Hz |
| Frequency Bandwidth | 2 Hz~30 MHz |
| Peak di/dt | 80 / 40 kA/µs (peak / continuous) |
| Sensitivity | 2 mV/A |
| Typical Accuracy | ±2% |
| Noise | 1.4 mV (rms, effective value) |
| Coil Withstand Voltage | 1.2 kV |
| Operating Temperature | -40~+125 °C |
| Zero Adjustment | Yes |
| Coil Diameter | Max 1.7 mm |
| Coil Length | 84±4 mm |
| Cable Length | 1.5 m |