Sapphire Technologies high-voltage differential probe SI-9010 voltage 700 V/7000 V high-frequency 70M 2500 VrmsCATI
  • Sapphire Technologies high-voltage differential probe SI-9010 voltage 700 V/7000 V high-frequency 70M 2500 VrmsCATI

Sapphire Technologies high-voltage differential probe SI-9010 voltage 700 V/7000 V high-frequency 70M 2500 VrmsCATI

Brand: Sapphire Instruments

Origin: Taiwan, China

SI-9010 voltage 700 V/7000 V high-frequency 70M (2500 VrmsCATI) high-performance high-voltage differential probe
Overview



The differential amplification principle of a high-voltage differential probe refers to a pair of signals being input into an amplification circuit simultaneously and then subtracted to obtain the original signal.


A differential amplifier is an amplifier composed of two transistors with identical parameter characteristics and directly coupled.

If signals of equal amplitude and the same phase are input to both input terminals, the output is zero, thereby overcoming zero drift.





 Typical applications of high-voltage differential probes:


  • Dynamic parameter measurement of SiC and GaN semiconductors

  • Evaluation of power supply system switching parameters

  • Floating ground voltage measurement of high-voltage inverters

  • Electric & hybrid vehicle electric drive systems

  • High-energy physics research


Specifications

SI-9010 Specifications

Parameter Specification
Bandwidth DC to 70MHz (-3dB)
Attenuation 1:100 / 1000
Accuracy ±2%
Rise Time
Input Impedance 10MΩ // 10pF each side to ground
Input Voltage
- Category CAT I
- Differential Range 700Vrms and ±700V(DC+Peak AC) @1/1005000Vrms and ±7000V(DC+Peak AC) @1/1000
- Common Mode Range 2500Vrms and ±7000V(DC+Peak AC) @1/100 & 1/1000
- Absolute Max. Voltage 2500Vrms and ±7000V(DC+Peak AC) @1/100 & 1/1000 in common mode5000Vrms and ±7000V(DC+Peak AC) @1/100 & 1/1000 in differential mode
Output Voltage
- Swing ±7V (into 50kΩ load)
- Offset (typical)
- Noise (typical) 0.9mVrms
- Source Impedance (typical) 50Ω (for using 1MΩ input system oscilloscope)
CMRR (typical) -80dB @ 50Hz, -60dB @ 20kHz
Ambient Operating Temperature -10 to 40℃
Ambient Storage Temperature -30 to 70℃
Ambient Operating Humidity Up to 85% RH
Ambient Storage Humidity Up to 85% RH
Power Requirements*
- Standard 4xAA cells
- Options Power leads, Mains adaptor* (6VDC/200mA or regulated 9VDC/120mA), USB power cord
Length of BNC Cable 90cm
Length of Input Leads 60cm
Weight 500g
Dimension (L×W×H) 202mm × 83mm × 38mm

Notes:

a. The supplied voltage must be less than 12V and greater than 4.4V, otherwise the probe could be damaged or can't operated properly.

b. Polarity is "+" inside and "-" outside. For wrong polarity, built-in circuit protects the probe, no danger or damage will occur.

c. When the voltage of the cells become too low, the power indicator on the panel will flicker.


Expand Sapphire Technologies high-voltage diffe

* Specifications are subject to change without notice.