Sapphire Technologies high-voltage differential probe SI-9010A voltage 700 V/7000 V high-frequency 70M 5000 VrmsCATI
  • Sapphire Technologies high-voltage differential probe SI-9010A voltage 700 V/7000 V high-frequency 70M 5000 VrmsCATI

Sapphire Technologies high-voltage differential probe SI-9010A voltage 700 V/7000 V high-frequency 70M 5000 VrmsCATI

Brand: Sapphire Instruments

Origin: Taiwan, China

SI-9010A voltage 700 V/7000 V high-frequency 70M (5000 VrmsCATI) high-performance high-voltage differential probe
Overview



The differential amplification principle of a high-voltage differential probe refers to a pair of signals being input into an amplification circuit simultaneously and then subtracted to obtain the original signal.


A differential amplifier is an amplifier composed of two transistors with identical parameter characteristics and configured using direct coupling.

If signals of the same magnitude and the same phase are input to the two input terminals, the output is zero, thereby overcoming zero drift.





Typical applications of high-voltage differential probes:


  • Measurement of dynamic parameters of SiC and GaN semiconductors

  • Evaluation of power supply system switching parameters

  • Measurement of floating ground voltages in high-voltage inverters

  • Electric & hybrid vehicle electric drive systems

  • High-energy physics research


Specifications

SI-9010A Specifications

Parameter Specification
Bandwidth DC to 70MHz (-3dB)
Attenuation 1:100 / 1000
Accuracy ±2%
Input Impedance 50MΩ // 10pF each side to ground
Input Voltage
- Category CAT I
- Differential Range* 700Vrms and ±700V (DC+Peak AC) @1/1005000Vrms and ±7000V (DC+Peak AC) @1/1000
- Common Mode Range* 5000Vrms and ±7000V (DC+Peak AC) @1/100 & 1/1000
- Absolute Max. Voltage* 5000Vrms and ±7000V (DC+Peak AC) @1/100 & 1/1000 (Differential or Common Mode)
Output Voltage
- Swing (into 50kΩ load) ±7V
- Offset (typical)
- Noise (typical) 0.9mVrms
- Source Impedance (typical) 50Ω (for using 1MΩ input system oscilloscope)
CMRR (typical) -80dB @ 50Hz, -60dB @ 20kHz
Ambient Operating Temperature -10 to 40℃
Ambient Storage Temperature -30 to 70℃
Ambient Operating Humidity Up to 85% RH
Ambient Storage Humidity Up to 85% RH
Power Requirements
- Standard 4xAA cells or 6VDC/200mA mains adaptor** or regulated 9VDC/120mA mains adaptor**
- Options Power leads
Length of BNC Cable 90cm
Length of Input Leads 60cm
Weight 500g
Dimension (L×W×H) 202mm × 83mm × 38mm
Notes:
* Voltage limit is the lesser of the DC+Peak AC and RMS values.
** a. The supplied voltage must be less than 12V and greater than 4.4V, otherwise the probe could be damaged or can’t operated properly.
b. Polarity is “+” inside and “-” outside. For wrong polarity, built-in circuit protects the probe, no danger or damage will occur.
c. When the voltage of the cells become too low, the power indicator on the panel will flicker.