Tektronix
Categories
Probemart.com | Probes, current sensors & calibration sources for pulsed-power testing
Bookmark
Tektronix
Categories

The TAP1500 single-ended active FET probe provides the excellent high-speed electrical and mechanical performance required by today's digital system designs.
Excellent electrical performance
≥1.5 GHz probe bandwidth
≤1 pF input capacitance
1 MΩ input resistance
-8 V to +8 V input dynamic range
-10 V to +10 VDC input offset range
Multiple mechanical features
Small, compact probe for probing small-geometry circuit components
DUT connection accessories can connect to SMDs with pitch as small as 0.5 mm
Rugged, reliable design
Ease of use
Direct connection to the oscilloscope via the TekVPI™ probe interface
Provides automatic unit scaling and readouts on the oscilloscope display
Easy access to the oscilloscope probe menu display for probe status/diagnostic information and control of probe DC offset
Remote GPIB/USB probe control through the oscilloscope
Applications
High-speed digital system design
Component design and characterization
Manufacturing engineering and testing
Education and research
Signals with voltage swing up to 16 V
≤1 pF input capacitance and 1 MΩ input resistance reduce DUT loading effects
Versatile DUT connection capable of connecting to small SMDs
Preserves instrument bandwidth at the probe tip for ≤1 GHz oscilloscopes
——— Related Applications ———
——— Related Products ———
PMK FireFly®FF-1500A optically isolated probe 1.3 GHz/1.5 GHz high CMRR (180 dB) high-voltage 2500 V double-pulse VGS gate /VDS drain voltage
IWATSU multi-channel high-voltage high-frequency optically isolated measurement probe Isolation SE-6000 remote UHV safety test system
CIC high-voltage differential probe DP20-20K-LVC high-precision 0.1% high-frequency isolated high CMRR 20 kV
Unless otherwise stated, all specifications are guaranteed.Unless otherwise specified, all specifications apply to all models.
The probe is powered directly by the oscilloscope with TekVPI probe interface.
Attenuation (3 only)
10X±2%
bandwidth (Only for probe)
≥1.5GHz
rise time (Only for probe)
Input capacitance
Input resistance
1 teraohm
Linear
±8V (16V)Peak-to-Peak)
Input bias range
±10 volts
Maximum Lossless Input Voltage
±15V (DC peak value AC)
Propagation delay
5.3 nanoseconds
Temperature
Operation
0°C to 50°C (32°F to 122°F)
Non-operational
-40 °C to 71 °C (-40 °F to 160 °F)
Humidity
Operation
5% to 95% relative humidity, up to 30 °C (86 °F)
Relative humidity 5% to 85% at 30°C to 50°C (86°F to 122°F)
Non-condensable
Non-operational
5% to 95% relative humidity, up to 30 °C (86 °F)
Relative humidity is 5% to 85% at 30 °C to 75 °C (86 °F to 167 °F)
Non-condensable
Height
Operation
up to 4,400 m (14,436 feet)
Non-operational
up to 12,192 m (40,000 feet)
Regulation
Compliance Label
WEEE (European Union)
probe Size
Height
4.83 millimeters (0.19 inches)
Width
7.87.1 millimeters (0.31 inches)
Length
59.18 millimeters (2.30 inches)
Other dimensions
Cable length
1300 mm (51 in)
Weight
Net
0.45 kg (1.0 lbs)