T&M Research
Categories
Probemart.com | Probes, current sensors & calibration sources for pulsed-power testing
Bookmark
T&M Research
Categories

Brand: T&M Research
Origin: USA
Probemart.com-T&M shunts_tech_NOTE 2023.pdf
SSDN-414-01 Datasheet & Dimension Drawing.pdf
T&M Coaxial Shunt Bench Test Report 7 CVR SHUNT Analysys REPORT-Rev7probemart.com.pdf
T&M Coaxial Shunt SSDN-414 Dimension Drawing 2024.PDF
PD-200X Overview (V2.0).pdf
Infineon-EvalBoard_TO247_PLUS-ApplicationNotes-v01_00-EN.pdf
Non-inductive coaxial shunt CVR (Current Viewing Resistor)
T&M CVR high-frequency non-inductive di resistor, designed for monitoring pulse generator systems, extremely high peak power and current inputs generated by steady-state current loads, and transient current monitoring. In recent years, with the rapid development of power semiconductors and wide-bandgap devices, dynamic performance (double-pulse) evaluation of devices requires high-precision capture of the current waveform at the instant of device turn-on and turn-off, while minimizing the insertion loss of the probe itself.
Main features:
GHz measurement bandwidth, picosecond-level measurement delay;
Patented technology, extremely low inductance;
Monitoring continuous signals (W) or high-energy pulses (J);
0.2% resistance accuracy;
Maximum power dissipation of 2 W per unit;
Universal BNC connector

—————————————————————————————
Typical applications:
Pulsed current applications
Calibration laboratories
Current sensing in phase meters
Single-phase angle indicator V-A
Three-phase angle indicator V-A
Power factor meter
High-frequency wattmeter
Wideband power meter
Power analysis
Current transformer calibration
Current probe phase delay characterization
SCR current measurement
Current control for automatic welding machines
Measurement of automotive alternator output
Fault current detection to determine alternator bearing wear
Electron-beam welding
Current sensing in knock systems
Three-phase fault testing in transmission substations
Fault detection in modulators
Measurement of lamp current in laser systems
IGBT chopper current control in electric vehicles
Circuit breaker testing
—————————————————————————————————————

The SDN series are non-inductive shunts designed to operate over a wide bandwidth and are suitable for AC and DC power systems; they are particularly critical in impedance measurement and power calibration systems where phase angle and propagation delay are considered. They are very useful for adding or extending the current range of power analyzers, power meters, phase-angle meters, frequency response analyzers, and multimeters. When used with a phase-angle meter, the SDN series can measure phase angle between voltage-voltage, voltage-current, or current-current, making them ideal for calibration of phase protection relays, electricity meters, and current transformers.
CVRs are rugged high-frequency resistors designed to withstand very high peak power and current inputs generated by capacitor banks, pulse generator systems, and steady-state current loads. Their linear response over a wide frequency band provides an accurate indication of current magnitude without inductive elements. Inherent in CVR design is the coupling among key electrical parameters such as resistance, bandwidth, energy capacity, and power rating. This means we offer a broad family of standard units covering a wide range of specifications.
Power rating
Although most CVRs are primarily designed for surge current measurement, their rugged construction and low-temperature-coefficient resistive elements make them ideal for many steady-state applications. Therefore, each resistor series cites an average power rating suitable for continuous current loads. In circuits involving AC or high-duty-cycle pulsed currents, care should be taken not to exceed this rating, because overheating can damage the CVR. If required, we can supply resistors with special constructions that increase the standard power rating to high values depending on the model.
Frequency response
The bandwidth of a CVR is essentially flat from DC to an upper limit, determined primarily by skin effect in the resistive element. The relevant bandwidth is based on the 10% to 90% rise-time response to a current step function generated by a coaxial-line pulse generator. The di/dt of the test pulse exceeds 10^12 A/s.
Resistance value
Unless otherwise specified, the resistance tolerance is ±4% of nominal value. In addition, each unit is supplied with an accurate resistance determination by Kelvin bridge, accurate to ±0.2%. We can provide a wide range of special resistance values for any of our standard units.
Mechanical design
All coaxial CVRs have silver-plated brass housing construction. The standard output signal connector is BNC; other connectors are available. Large coaxial CVRs use high-current flanges and coaxial threaded-stud input connections. Powertek's flat-configuration CVRs, the W series, were originally developed for flat-plate transmission-line mounting, offer a wide range of unit widths and input configurations, and have been found particularly useful in applications requiring resistors with very high energy and power ratings.
Global traceability
All measurements made with CVR series SDN shunts are traceable to national and international standards through Powertek's measurement standards. All CVR series SDN shunts are supplied with certificates of conformity required by quality assurance standards such as IEC17025 / ISO9001. Independent measurement certification can be provided using UKAS, A2LA, or Z540 / NAVLAP certificates.
For more content, follow the "探头之家" WeChat official account.

——— Related Applications ———
——— Related Products ———
PMK FireFly®FF-1500A optically isolated probe 1.3 GHz/1.5 GHz high CMRR (180 dB) high-voltage 2500 V double-pulse VGS gate /VDS drain voltage
IWATSU multi-channel high-voltage high-frequency optically isolated measurement probe Isolation SE-6000 remote UHV safety test system
CIC high-voltage differential probe DP20-20K-LVC high-precision 0.1% high-frequency isolated high CMRR 20 kV
Model |
Resistance ohms |
Bandpass MHz. |
Risetime nsec. |
Emax joules |
SDN-414-01 |
0.01 |
400 |
1 |
6 |
SSDN-414-01 |
0.01 |
400 |
1 |
6 |
SPT-414-01 |
0.01 |
400 |
1 |
6 |
SDN-414-025 |
0.025 |
1200 |
0.3 |
3 |
SSDN-414-025 |
0.025 |
1200 |
0.3 |
3 |
SPT-414-025 |
0.025 |
1200 |
0.3 |
3 |
SDN-414-05 |
0.05 |
2000 |
0.18 |
2 |
SSDN-414-05 |
0.05 |
2000 |
0.18 |
2 |
SPT-414-05 |
0.05 |
2000 |
0.18 |
2 |
SDN-414-10 |
0.1 |
2000 |
0.18 |
1 |
SSDN-414-10 |
0.1 |
2000 |
0.18 |
1 |
SPT-414-10 |
0.1 |
2000 |
0.18 |
1 |
US precision instruments, NMR research results, patented technology, low inductance, ultra-high-precision resistors, high overload capacity, particularly suitable for pulse current monitoring; additional specifications can be customized.